11 results
Practical Approach to Grading Diastolic Dysfunction

#Diagnosis #Cardiology #Diastolic #Diastology #Dysfunction #Grading #Classification #Grades #Criteria #Algorithm #Assessment
Grading Diastolic Dysfunction ... #Diagnosis #Cardiology ... #Grading #Classification ... #Grades #Criteria ... #Algorithm #Assessment
Diastolic Function Grading - Schematic diastolic filling patterns

I: impaired relaxation, II: moderate diastolic dysfunction (pseudonormal), III:
moderate diastolic dysfunction ... #Diagnosis #Cardiology ... #Grading #Classification ... #Grades #Criteria ... #Table #Assessment
Algorithm for Diagnosing Diastolic Dysfunction With Doppler Echocardiography
 1. Determine the age of the patient
Algorithm for Diagnosing ... Grade diastolic ... pressure (LVFP): #Algorithm ... Echocardiography #Cardiology ... Diagnosis #Grading #Classification
Diastolic Dysfunction Assessment - Normal, Mild, Moderate and Severe

#Diastolic #Diastology #Dysfunction #Diagnosis #Cardiology #Grading #Classification #Grades
Diastolic Dysfunction ... #Diagnosis #Cardiology ... #Grading #Classification ... #Grades #Criteria ... #Table #Assessment
Estimated Medical Radiation Doses for 5 Year-Old Child

3-view ankle	0.0015 mSv	1/14th CXRs
2-view chest	0.02 mSv	1 CXRs
Anteroposterior and lateral
Medical Radiation Doses ... #PatientInfo #Radiology ... #Imaging #ChestXRay ... Nuclear #Comparison #Table ... #Risks #Testing
Hypomagnesemia - Etiologies by Mechanism

Decreased GI Uptake 
 - Poor dietary intake (particularly common in alcoholics)
/ IBD Renal Loses ... renal tubular dysfunction ... Familial renal Mg wasting ... Low #Magnesium #Table ... #Classification
Radiation Dose to Adults from Common Imaging Examinations
ABDOMINAL REGION
 - Computed Tomography (CT) — Abdomen and
Radiation Dose to ... #PatientInfo #Radiology ... #Imaging #ChestXRay ... Nuclear #Comparison #Table ... #Risks #Testing
Preoperative Risk Evaluation

Major Pre-Op Questions:
1. Does the patient have any modifiable risk factors that could be
event, follow ACC algorithm ... with valvular dysfunction ... or LV dysfunction ... one post op Cardiology ... preoperative stress testing
How much radiation is used in paediatric radiology examinations compared to other exposures?

Estimated dose - Days
Estimated dose - ... Background #Radiation #Doses ... #Imaging #ChestXRay ... Nuclear #Comparison #Table ... #Risks #Testing
 The following #reflexes are routinely tested, and the response elicited is graded from zero to
response elicited is graded ... patellar reflex testing ... the edge of a table ... , frontal lobe dysfunction ... reflex suggests dysfunction