14 results
Mains Electricity Failure - Guidelines for Crises in Anaesthesia
Unexpected total power failure is rare and unpredictable.
for Crises in Anaesthesia ... • If immediate evacuation ... ❻ Check mains oxygen ... • Consider evacuation ... Anesthesiology #Anesthesia
Intraoperative Hypertension - Guidelines for Crises in Anaesthesia
Hypertension is most commonly due to inappropriate depth of
for Crises in Anaesthesia ... problem in adequate oxygen ... stimulus. ❷ Adequate oxygen ... check measured FiO2 ... Anesthesiology #Anesthesia
Hypotension - Guidelines for Crises in Anaesthesia

Hypotension is commonly due to unnecessarily deep anaesthesia, the autonomic
problem in adequate oxygen ... ❶ Adequate oxygen ... AND give 100% oxygen ... check measured FiO2 ... Anesthesiology #Anesthesia
Cardiac Arrest - Guidelines for Crises in Anaesthesia

The probable cause is one or more of: something
delegate task of evaluating ... ). ❷ Adequate oxygen ... flow, give 100% oxygen ... check measured FiO2 ... Anesthesiology #Anesthesia
Difficult Airway Algorithm

1. Assess the likelihood and clinical impact of basic management problems: 
 • Difficulty
Difficult Airway Algorithm ... deliver supplemental oxygen ... induction of general anesthesia ... Difficult #airway #algorithm ... Anesthesiology #Anesthesia
Intraoperative Tachycardia - Guidelines for Crises in Anaesthesia
Tachycardia in theatre is often due to inadequate depth
for Crises in Anaesthesia ... inadequate depth of anaesthesia ... analgesia. ❷ Adequate oxygen ... check measured FiO2 ... Anesthesiology #Anesthesia
Increased Airway Pressure - Guidelines for Crises in Anaesthesia

Using these steps from start to end should
for Crises in Anaesthesia ... . ❶Adequate oxygen ... AND give 100% oxygen ... check measured FiO2 ... Anesthesiology #Anesthesia
Intraoperative  Bradycardia - Guidelines for Crises in Anaesthesia
Bradycardia in theatre should not be treated as
for Crises in Anaesthesia ... B. ❷ Adequate oxygen ... check measured FiO2 ... for crises in anaesthesia ... Anesthesiology #Anesthesia
Intraoperative Mains Oxygen Supply Failure - Guidelines for Crises in Anaesthesia

Complete failure of wall or pendant
for Crises in Anaesthesia ... lowest possible FiO2 ... • Check FiO2 ... for crises in anaesthesia ... Anesthesiology #Anesthesia
Adult Post–Cardiac Arrest Care Algorithm - AHA2020
Initial Stabilization Phase - Resuscitation is ongoing during the post-ROSC
Post–Cardiac Arrest Care Algorithm ... parameters: Titrate FiO2 ... Activities - These evaluations ... intervention: Early evaluation ... ROSC #PostArrest #algorithm