14 results
Oxygen delivery & ABG interpretation made easier with this simple colour-coded table. Please share, and print
Oxygen delivery ... SupplementalO2 #Oxygen ... Devices #Interfaces #FiO2 ... FaceMask #NRB #FlowRates
Nasal Oxygen Delivery Devices
Nasal cannula can be used to deliver supplemental O2. Conventional nasal cannula are
Nasal Oxygen Delivery ... rates & moderate FiO2 ... achieving a higher FiO2 ... hypoxemic respiratory failure ... nickmmark #Nasal #Oxygen
Perform computations online at:
ScyMed.com
6th ED
ICU-card
«ICU, Formulas & Drugs»
HEMODYNAMIC PATTERNS
Condition
SAP
CVP

PAP PCWP

CO C(a-v)02 PVR

SVR
Hypovolemic shock
↓
↓
↓
↓
↓
↑
↑
↑
Cardiogenic shock
↓
1
↑
1

1
↑

Septic shock
↓
↓
↓
↓
↑
↓
↓
↓
Cardiac Tamponade
.
↑
↑
1
↓

→
↑
RV
Index CARDIAC WORK ... A-a Gradient (((FIO ... Tension ((FIO) ... 100-150 mmHg (FIO2 ... Barometric Pressure FIO2
Intraoperative Mains Oxygen Supply Failure - Guidelines for Crises in Anaesthesia

Complete failure of wall or pendant
Supply Failure ... , but be aware failure ... lowest possible FiO2 ... • Check FiO2 ... Diagnosis #Management #Workup
Mains Electricity Failure - Guidelines for Crises in Anaesthesia
Unexpected total power failure is rare and unpredictable.
Mains Electricity Failure ... Unexpected total power failure ... ❻ Check mains oxygen ... #Electricity #Failure ... Diagnosis #Management #Workup
Intraoperative Hypertension - Guidelines for Crises in Anaesthesia
Hypertension is most commonly due to inappropriate depth of
problem in adequate oxygen ... stimulus. ❷ Adequate oxygen ... check measured FiO2 ... interaction, renal failure ... Diagnosis #Management #Workup
Hypotension - Guidelines for Crises in Anaesthesia

Hypotension is commonly due to unnecessarily deep anaesthesia, the autonomic
problem in adequate oxygen ... ❶ Adequate oxygen ... AND give 100% oxygen ... check measured FiO2 ... Diagnosis #Management #Workup
Cardiac Arrest - Guidelines for Crises in Anaesthesia

The probable cause is one or more of: something
surgery; equipment failure ... ). ❷ Adequate oxygen ... flow, give 100% oxygen ... check measured FiO2 ... Diagnosis #Management #Workup
Increased Airway Pressure - Guidelines for Crises in Anaesthesia

Using these steps from start to end should
. ❶Adequate oxygen ... AND give 100% oxygen ... check measured FiO2 ... Diagnosis #Management #Workup
Intraoperative  Bradycardia - Guidelines for Crises in Anaesthesia
Bradycardia in theatre should not be treated as
B. ❷ Adequate oxygen ... check measured FiO2 ... Diagnosis #Management #Workup