14 results
APVcmv - Adaptive Pressure Ventilation - Controlled Mechanical Ventilation Summary
Most Similar to PRVC - Pressure Regulated
Adaptive Pressure Ventilation ... Controlled Mechanical Ventilation ... Volume 3) PEEP 4) FiO2 ... Happening - The ventilator ... patients - The more work
Volume Assist/Control Mechanical Ventilation
How does this mode work?
 • Delivers a set volume of air with
Control Mechanical Ventilation ... does this mode work ... Lung Protective Ventilation ... initial minute ventilation ... PEEP and high Fi02
ASV - Adaptive Support Ventilation Summary
Basic Set Parameters:
  1) Target MV (80-120%)
  2) PEEP
Adaptive Support Ventilation ... 2) PEEP 3) FiO2 ... determine ideal minute ventilation ... lowest amount of work ... Support #Mechanical #Ventilation
SPONT - Spontaneous Breathing = Pressure Support Ventilation Summary
Basic Set Parameters:
  1) Pressure Support (PS)
Pressure Support Ventilation ... 2) PEEP 3) FiO2 ... do some of the work ... means the patient ↑work ... Support #mechanical #Ventilation
Increased Airway Pressure - Guidelines for Crises in Anaesthesia

Using these steps from start to end should
check measured FiO2 ... bag moving OR ventilator ... switching to hand ventilation ... Diagnosis #Management #Workup
Perform computations online at:
ScyMed.com
6th ED
ICU-card
«ICU, Formulas & Drugs»
HEMODYNAMIC PATTERNS
Condition
SAP
CVP

PAP PCWP

CO C(a-v)02 PVR

SVR
Hypovolemic shock
↓
↓
↓
↓
↓
↑
↑
↑
Cardiogenic shock
↓
1
↑
1

1
↑

Septic shock
↓
↓
↓
↓
↑
↓
↓
↓
Cardiac Tamponade
.
↑
↑
1
↓

→
↑
RV
Index CARDIAC WORK ... RCWI Cardiac Work ... VT*RR Minute Ventilation ... 100-150 mmHg (FIO2 ... Barometric Pressure FIO2
Cardiac Arrest - Guidelines for Crises in Anaesthesia

The probable cause is one or more of: something
check measured FiO2 ... Rapidly confirm ventilator ... provide manual ventilation ... Diagnosis #Management #Workup
Intraoperative Hypertension - Guidelines for Crises in Anaesthesia
Hypertension is most commonly due to inappropriate depth of
check measured FiO2 ... bag moving OR ventilator ... Diagnosis #Management #Workup
Intraoperative  Bradycardia - Guidelines for Crises in Anaesthesia
Bradycardia in theatre should not be treated as
check measured FiO2 ... bag moving OR ventilator ... Diagnosis #Management #Workup
Intraoperative Tachycardia - Guidelines for Crises in Anaesthesia
Tachycardia in theatre is often due to inadequate depth
check measured FiO2 ... bag moving OR ventilator ... Diagnosis #Management #Workup