38 results
Estimated Medical Radiation Doses for 5 Year-Old Child

3-view ankle	0.0015 mSv	1/14th CXRs
2-view chest	0.02 mSv	1 CXRs
Anteroposterior and lateral
Medical Radiation Doses ... and lateral abdomen ... #PatientInfo #Radiology ... #CT #Nuclear #Comparison ... #Table #Risks #
Treatment of Stable Narrow-Complex Tachycardia
Regular Rhythm:
 • Attempt vagal maneuvers
 • Give adenosine 6 milligrams IV
Repeat 12-milligram dose ... - Observe and ... Treat underlying cause ... Tachycardia #Treatment #management ... #cardiology #algorithm
Vasopressors Table 
Rough properties by Target Receptor, Heart Rate/Inotropy, Systemic Vascular Resistance, Cardiac Output, Blood Pressure,
Vasopressors Table ... Blood Pressure, Pulmonary ... Resistance, Main Uses ... Pharmacology #Effect #Management ... #Comparison #Inotropes
Adult ACLS - Cardiac Arrest Algorithm - AHA 2020
CPR Quality:
 • Push hard (at least 2
Algorithm - AHA 2020 CPR ... recommendation (eg ... intra-arterial Reversible Causes ... , Thrombosis, (pulmonary ... Algorithm #AHA2020 #management
Radiation Dose to Adults from Common Imaging Examinations
ABDOMINAL REGION
 - Computed Tomography (CT) — Abdomen and
Radiation Dose to ... #PatientInfo #Radiology ... Imaging #ChestXRay #CXR ... #CT #Nuclear #Comparison ... #Table #Risks #
Adult Cardiac Arrest - ACLS Circular Algorithm - AHA 2020
CPR Quality:
 • Push hard (at least
Algorithm - AHA 2020 CPR ... recommendation (eg ... intra-arterial Reversible Causes ... , Thrombosis, (pulmonary ... Algorithm #AHA2020 #management
Acute Respiratory Distress Syndrome – ARDS: Clinical Cheat Sheet

An acute diffuse, inflammatory lung injury, leading to
leading to increased pulmonary ... consistent with pulmonary ... detected on CT or CXR ... objective assessment“ (e.g ... the underlying cause
Stage I - Redistribution
In a normal chest film with the patient standing erect, the pulmonary vessels
standing erect, the pulmonary ... The pulmonary vascular ... In these cases comparison ... #Clinical #Radiology ... #CXR #CHF #Cephalization
Cardiac Event Monitoring Devices - Compared
Ambulatory ECG (Hotter):
 • Advantages: Continuous recording, records asx events, all
Compared Ambulatory ECG ... events, all (most) ECG ... Disadvantages: Does ... Monitoring #Devices #Comparison ... #cardiology #management
How much radiation is used in paediatric radiology examinations compared to other exposures?

Estimated dose - Days
in paediatric radiology ... Estimated dose - ... Imaging #ChestXRay #CXR ... #CT #Nuclear #Comparison ... #Table #Risks #