Oxygen Delivery Systems and Approximate FiO2:
#Management #SupplementalO2 #Oxygen #Delivery #Devices #Interface #FiO2 #NonRebreather #HFNC #NasalCannula #Simple
and Approximate FiO2 ... Oxygen #Delivery #Devices ... #Interface #FiO2 ... FaceMask #Venture #Table
Oxygen delivery & ABG interpretation made easier with this simple colour-coded table. Please share, and print
simple colour-coded table ... Oxygen #Delivery #Devices ... #Interfaces #FiO2 ... NRB #FlowRates #Table
Oxygen Delivery Devices - Comparison
Low Flow:
 • Nasal cannula (1-6L, 24-40% FiO2)
 • Face mask (5-10L,
Oxygen Delivery Devices ... (1-6L, 24-40% FiO2 ... (5-10L, 35-60% FiO2 ... Oxygen #Delivery #Devices ... #Comparison #table
Algorithm for Suspected Cardiovascular Implantable Electronic Device (CIED) Pocket Infection
Algorithm for Management of bacteremia without evidence
Algorithm for Suspected ... Implantable Electronic Device ... #Pocket #device ... #infection #Algorithm ... cardiology #CIED #IDSA
Intraoperative Sepsis - Guidelines for Crises in Anaesthesia

Severe sepsis (hypotension persisting after initial fluid challenge of
Intraoperative Sepsis ... problem. ❷ Increase FiO2 ... seek microbiology advice ... whether indwelling devices ... Anesthesiology #Anesthesia #Intraoperative
Intraoperative Hypertension - Guidelines for Crises in Anaesthesia
Hypertension is most commonly due to inappropriate depth of
Intraoperative Hypertension ... check measured FiO2 ... position of airway device ... Confirm airway device ... Anesthesiology #Anesthesia #Intraoperative
Intraoperative  Bradycardia - Guidelines for Crises in Anaesthesia
Bradycardia in theatre should not be treated as
Intraoperative ... check measured FiO2 ... position of airway device ... Confirm airway device ... Anesthesiology #Anesthesia #Intraoperative
Intraoperative Tachycardia - Guidelines for Crises in Anaesthesia
Tachycardia in theatre is often due to inadequate depth
Intraoperative Tachycardia ... check measured FiO2 ... position of airway device ... Confirm airway device ... Anesthesiology #Anesthesia #Intraoperative
Increased Airway Pressure - Guidelines for Crises in Anaesthesia

Using these steps from start to end should
check measured FiO2 ... position of airway device ... Confirm airway device ... whether airway device ... Anesthesiology #Anesthesia #Intraoperative
Hypotension - Guidelines for Crises in Anaesthesia

Hypotension is commonly due to unnecessarily deep anaesthesia, the autonomic
check measured FiO2 ... position of airway device ... airway AND airway device ... Anesthesiology #Anesthesia #Intraoperative