43 results
Swan Ganz - Pulmonary Artery Catheter Basics

Nick Mark MD @nickmmark

#PA #SwanGanz #Pulmonary #Artery #Catheter #Basics #Diagnosis
Swan Ganz - Pulmonary ... Artery Catheter ... #Artery #Catheter ... Basics #Diagnosis #Management ... CriticalCare #ICU #pressures
Pulmonary Artery Catheter Pressures
Normal: RA 0-8, RV 15-25/0-8, Mean PAP <25, PCWP 8-12, Cardiac Index 2.6-4.2
HFrEF,
Pulmonary Artery ... Catheter Pressures ... decompensated Pulmonary ... #Artery #Catheter ... #Pressures #Wedge
Algorithm for Management of peritoneal dialysis catheter-associated mechanical complications in urgent start peritoneal dialysis.

#peritoneal #dialysis #pd
Algorithm for Management ... peritoneal dialysis catheter-associated ... #dialysis #pd #algorithm ... #management #complications
Upper Extremity Venous Thrombosis - Management and Anatomy

Deep - Superficial - Catheter Associated

#UpperExtremity #Veins #Venous #Thrombosis
Venous Thrombosis - Management ... Superficial - Catheter ... DVT #Hematology #Management ... Anticoagulation #Algorithm
Algorithm for Interpreting Urine Studies in a Patient with a Foley Catheter

- Dr. Catherine Liu

#Foley #Urinalysis
Algorithm for Interpreting ... Patient with a Foley Catheter ... UTI #Diagnosis #Algorithm ... #Management
Suspected catheter-related bloodstream infection - Management Algorithm
 • Temperature 37.8 C   • Rigors
Suspected catheter-related ... cultures from the catheter ... arthritis) Keep catheter ... infection Remove catheter ... infection #catheter
Pulmonary Arterial Catheterization – Use and Interpretation:
-Pulmonary arterial catheterization (PAC) has never been shown to improve
artery occlusion pressure ... capillary wedge pressure ... -right atrial pressure ... #Diagnosis #PACatheter ... #Wedge #PCWP #Pressures
Intraoperative Hypertension - Guidelines for Crises in Anaesthesia
Hypertension is most commonly due to inappropriate depth of
Recheck blood pressure ... passing suction catheter ... Feel the airway pressure ... raised intracranial pressure ... Checklist #Diagnosis #Management
Intra-Aortic Balloon Pump (IABP)

Intra-aortic balloon counter-pulsation is a method of invasive hemodynamic support. A catheter is
A catheter is placed ... the end of the catheter ... increasing diastolic pressure ... Triggers (EKG, Pressure ... Pump #diagnosis #management
Increased Airway Pressure - Guidelines for Crises in Anaesthesia

Using these steps from start to end should
for Crises in Anaesthesia ... passing suction catheter ... o Aspiration, pulmonary ... Anesthesiology #Anesthesia ... Checklist #Diagnosis #Management