61 results
Primary Adrenal Insufficiency:
 • ACTH stimulation test - Synthetic ACTH does not stimulate cortisol secretion because
stimulation test ... stimulation test ... stimulation test ... Insufficiency #Evaluation #laboratory ... #diagnosis #testing
Diagnosis Adrenal Insufficiency - Algorithm

Step 1) Screening Test: 6-8AM Cortisol Level
 - Early morning cortisol levels
Insufficiency - Algorithm ... Step 1) Screening Test ... require Cosyntropin testing ... ) Confirmation Test ... This test determines
Adrenal Insufficiency Differential Diagnosis Algorithm
Clinical suspicion: Weakness, fatigue, nausea, musculoskeletal pain, dizziness, volume depletion, abdominal pain,
Differential Diagnosis Algorithm ... , hypoglycemia Testing ... ) stimulation test ... High baseline ACTH ... Differential #Diagnosis #Algorithm
Testing for Diabetes Type II
 - 
Hemoglobin A1c test
 - Random blood sugar test
 - Fasting
Hemoglobin A1c test ... Random blood sugar test ... sugar test - Oral ... glucose tolerance test ... #A1c #Glucose #Laboratory
Adrenal Insufficiency Diagnosis Algorithm - Evaluation of HPA Axis Response to ACTH

Early am cortisol < 3
Insufficiency Diagnosis Algorithm ... then go to stim testing ... Standard Stim test ... #ACTH #Stimulation ... #Test #Endocrinology
COVID-19 PCR and Serology Testing - Timeline
 • Nucleic Acid Test - Most reliable and can
PCR and Serology Testing ... • Nucleic Acid Test ... days • Antibody Test ... 10 days Both tests ... #laboratory #Timeline
Adrenal Insufficiency Diagnosis Algorithm
Clinical features: 
 - Weight loss, anorexia, Weakness, fatigue, GI distress
 - Hypotension,
Insufficiency Diagnosis Algorithm ... skin (due to high ACTH ... stimulating melanocytes ... test: Steroids ... interact with stim test
Algorithm for the diagnosis of adrenal insufficiency (AI). The standard cosyntropin stimulation test (CST) may be
Algorithm for the ... standard cosyntropin stimulation ... test (CST) may ... the first-line test ... Diagnosis #Endo #ACTH
Adrenal Insufficiency Algorithm - Cosyntropin Stimulation Test
T-1m: Baseline cortisol drawn
T0: 250 µg cosyntropin given IV
T30m: Repeat
Insufficiency Algorithm ... - Cosyntropin Stimulation ... Test T-1m: Baseline ... Insufficiency #Testing ... #Algorithm #Cosyntropin
Adrenal Insufficiency Diagnosis Algorithm
Test 1: Baseline AM Cortisol 
 - Beware of major normal value
 -
Insufficiency Diagnosis Algorithm ... Test 1: Baseline ... OCPs, pregnancy) Test ... 2: ACTH Stimulation ... Insufficiency #Diagnosis #Algorithm