Effective radiation dose in adults - Following are comparisons of effective radiation dose in adults with
Effective radiation ... Following are comparisons ... ChestXRay #CXR #CT ... #Nuclear #Comparison ... #Table #Risks
Estimated Medical Radiation Doses for 5 Year-Old Child

3-view ankle	0.0015 mSv	1/14th CXRs
2-view chest	0.02 mSv	1 CXRs
Anteroposterior and lateral
Estimated Medical Radiation ... Radiology #Background #Radiation ... #Nuclear #Comparison ... #Table #Risks # ... Testing #Study #
Imaging options for exclusion of PE in pregnant women
The radiation dose required for either V/Q scanning
pregnant women The radiation ... /Q scanning or CT-PA ... fetal dose of radiation ... Workup #Imaging #Comparison ... #Table #Pregnant
Radiation Dose to Adults from Common Imaging Examinations
ABDOMINAL REGION
 - Computed Tomography (CT) — Abdomen and
Radiation Dose to ... Radiology #Background #Radiation ... #Nuclear #Comparison ... #Table #Risks # ... Testing #Study
Syncope Diagnostic Testing and Evaluation: Cost Effectiveness
Frequency obtained - Abnormal findings - Helped determine etiology of
Syncope Diagnostic Testing ... enzymes, Head CT ... diagnosis #workup #testing ... Effectiveness #table ... #comparison
Medical Imaging - Radiation Dose
#PatientInfo #Radiology #Procedures #Imaging #Radiation #Doses #ChestXRay #CT #Nuclear #Stress #Comparison #Table
Medical Imaging - Radiation ... Procedures #Imaging #Radiation ... Doses #ChestXRay #CT ... Nuclear #Stress #Comparison ... #Table #Risks
How much radiation is used in paediatric radiology examinations compared to other exposures?

Estimated dose - Days
How much radiation ... of background radiation ... #Nuclear #Comparison ... #Table #Risks # ... Testing #Study #
Small Bowel Obstruction Testing Accuracy
#Diagnosis #SBO #Testing #Accuracy #Sensitivity #Specificity #KUB #AbdominalXRay #CT #POCUS #LikelihoodRatio #Comparison
Bowel Obstruction Testing ... Diagnosis #SBO #Testing ... AbdominalXRay #CT ... LikelihoodRatio #Comparison ... #Table
Vasopressors and Inotropes
 • Norepinephrine - Levophed - "Levo" - Generally thought of as the first
(arrhythmia in setting ... Inotropes #management #criticalcare ... #summary #comparison ... #table #pharmacology
Fluid Responsiveness and Fluid Tolerance Testing - OnePager Summary
Fluid resuscitation can be beneficial when required or
Fluid Tolerance Testing ... continuous (via heating ... Responsiveness #Tolerance #testing ... #diagnosis #criticalcare ... #comparison #challenges