16 results
Lab patterns seen in Inborn Errors of Metabolism

A table of lab values compiled from UpToDate and
Lab patterns seen ... Metabolism A table ... of lab values compiled ... metabolicemergency-pathophysiology-differential-pediatrics-metabolism-algorithm-diagnosis ... Peds #Pediatrics #Table
Nodular pattern(2)
1. Sarcoidosis: nodules with perilymphatic distribution, along fissures, adenopathy.
2. TB: Tree-in-bud appearance in a patient
Nodular pattern( ... TB: Tree-in-bud appearance ... #Clinical #Radiology ... CTChest #Nodular #Pattern ... #Comparison #Table
Low Attenuation pattern 
1. Lymphangiomyomatosis (LAM): uniform cysts in woman of child-bearing age; no history of
Low Attenuation pattern ... Lymphangiomyomatosis (LAM ... #Clinical #Radiology ... LowAttenuation #Cystic #Pattern ... #Comparison #Table
Low Attenuation pattern (2) 
1. Centrilobular emphysema: low attenuation areas without walls. Notice the centrilobular artery
Low Attenuation pattern ... Lymphangiomyomatosis (LAM ... #Clinical #Radiology ... LowAttenuation #Cystic #Pattern ... #Comparison #Table
On the left some diseases with a nodular pattern.
1. Hypersensitivity pneumonitis: ill defined centrilobular nodules.
2. Miliary
with a nodular pattern ... TB: Tree-in-bud appearance ... Clinical #Diagnosis #Radiology ... #Differential #Comparison ... #Table #RadiologyAssistant
Appearance of Liver Lesions on Various Imaging Modalities
 • Computed Tomography (CT) - Arterial Phase, Portal
Appearance of Liver ... Arterial Phase, Portal ... CT #MRI #POCUS #radiology ... differential #diagnosis #comparison ... #table #appearance
Severity of Aortic Stenosis in Adults 
Current ACC/AHA guidelines recommend cut-off values for Doppler-echocardiographic measurements of
recommend cut-off values ... >50 mmHg (2) (Table ... with impaired and normal ... A common pattern ... #Diagnosis #Cardiology
Severe Mitral Stenosis- The physical examination revealed a right parasternal heave, a loud S1, a midpeaking
video and Panel A; LA ... square meter (normal ... continuous-wave Doppler flow pattern ... was 14 mm Hg (normal ... clinical #doppler #radiology
TISSUE APPEARANCES ON 
MUSCULOSKELETAL ULTRASOUND 

Bone:
 
Bone is represented as a very bright structure and appears
echotexture of normal ... Tendon: Normal ... the fibrillar pattern ... Atlas #Clinical #Radiology ... #Comparison
Appearance of Liver Lesions on Computed Tomography (CT) - Arterial Phase, Portal Venous Phase and Delayed
Appearance of Liver ... Arterial Phase, Portal ... ComputedTomography #CT #radiology ... differential #diagnosis #comparison ... #table #appearance