Forced vital capacity (FVC) curves comparing normal, obstructive, and restrictive disorders. Curves are as they appear
curves comparing normal ... commonly available spirometers ... Diagnosis #Pulmonary #Spirometry ... #Restrictive #Normal ... #Comparison
Patterns of pulmonary dysfunction revealed by flow-volume loops. For comparison, a normal loop is shown with
Patterns of pulmonary ... For comparison, ... a normal loop is ... Diagnosis #PFTs #Spirometry ... #Comparison #Normal
Flow Volume Loops - Common Patterns
A. Normal
B. Emphysema
C. Unilateral Main Stem Bronchial Obstruction
D. Fixed Upper Airway
Loops - Common Patterns ... Normal B. ... Diagnosis #PFTs #Spirometry ... FlowVolume #Loops #Patterns
Asthma vs COPD Presentation and Diagnosis
Asthma:
 • Epidemiology: Age usually < 45, History (personal or family)
spirometry - FEV1 ... bronchodilator, Spirometry ... often normal or ... spirometry - FEV1 ... #Asthma #COPD #comparison
First-line therapies for Asthma, Asthma-COPD Overlap and COPD

The diagnosis of COPD, asthma, and ACO initially requires
of the type and pattern ... symptoms, and spirometry ... #Diagnosis #Management ... Overlap #FirstLine #Differences ... #Algorithm #Treatment
Possible approach to empiric anticoagulation in COVID-19

Is D-dimer above '"1,000-2,000 ng/ml?
Contraindication to anticoagulation?
Check fibrinogen level and/or
hyper-coagulable pattern ... R-time low or normal ... Hypo-coagulable pattern ... anticoagulation #COVID19 #management ... #criticalcare #algorithm