11 results
APVcmv - Adaptive Pressure Ventilation - Controlled Mechanical Ventilation Summary
Most Similar to PRVC - Pressure Regulated
Mechanical Ventilation ... Rate 2) Target Tidal ... neurogenic breathing patterns ... target volume Casey ... #Mechanical #Ventilation
Capnography
Measurement of exhaled carbon dioxide can be used to confirm ETT placement, for safer procedural sedation,
• PETCO2 - End-tidal ... The Capnograph waveform ... dysynchrony during mechanical ... interpretation #waveforms ... #patterns #diagnosis
(S)CMV - Synchronized Controlled Mechanical Ventilation Summary
Most Similar to "AC/VC"
Basic Set Parameters:
  1) Rate
Synchronized Controlled Mechanical ... 1) Rate 2) Tidal ... sensitivity, flow pattern ... Casey Albin, MD ... Synchronized #Controlled #Mechanical
Arterial Lines & Waveforms
Arterial lines permit continuous invasive blood pressure measurement, frequent arterial blood sampling, and
Arterial Lines & Waveforms ... PATTERNS • Pulsus ... Ventilation (either ... spontaneous or mechanical ... and causes stroke
Basics of Waveform Capnography
Waveform capnography assesses ventilation by monitoring exhaled carbon dioxide
Can use measurement and morphology
capnography assesses ventilation ... Capnography measures ventilation ... rebreathing or mechanical ... peak, not end-tidal ... surface - Pattern
Mechanical ventilation in obese patients according to the i-STAR Algorithm
Intubate
 • Anticipate difficult airway management and
Mechanical ventilation ... to the i-STAR Algorithm ... • Tidal volume ... patients #iSTAR #Algorithm ... #Obesity #Mechanical
SPONT - Spontaneous Breathing = Pressure Support Ventilation Summary
Basic Set Parameters:
  1) Pressure Support (PS)
Support Ventilation ... determines the rate and tidal ... Most common cause ... (pulling good tidal ... #Support #mechanical
In ARDS, we know that the lungs are so diffusely injured that the remaining total area
the lungs are so diffusely ... injury may be diffuse ... see heterogenous patterns ... lung protective ventilation ... minimize the risk of Ventilator-Induced
Adult ACLS - Cardiac Arrest Algorithm - AHA 2020
CPR Quality:
 • Push hard (at least 2
Cardiac Arrest Algorithm ... Avoid excessive ventilation ... :2 compression-ventilation ... • Quantitative waveform ... intra-arterial Reversible Causes
Adult Cardiac Arrest - ACLS Circular Algorithm - AHA 2020
CPR Quality:
 • Push hard (at least