15 results
REBEL Review 4 & 5: Paralytic & Vasopressor Dosing 

Paralytic Agents:
 - Succinylcholine (Depolarizing Agent)
Paralytic Agents ... (Depolarizing Agent ... resuscitation #table ... #criticalcare #pharmacology ... #medications #Comparison
Clinician's Pocket Guide to Vasopressors - Receptor Profiles and Hemodynamic Parameters
 • Systemic Vascular Resistance -
Pocket Guide to Vasopressors ... Systolic BP)) / 3 • Cardiac ... #Pharmacology # ... cheatsheet #management #comparison ... #table #receptors
Vasopressors Table 
Rough properties by Target Receptor, Heart Rate/Inotropy, Systemic Vascular Resistance, Cardiac Output, Blood Pressure,
Vasopressors Table ... Vascular Resistance, Cardiac ... #Properties #Table ... #Pharmacology # ... Effect #Management #Comparison
Common Vasopressors and Inotropes
Norepinephrine (NE)
 - Indication: Distributive shock (1st line for septic shock), Cardiogenic shock
Common Vasopressors ... Can be used in all ... ischemia #Vasopressors ... #Inotropes #comparison ... #table #pharmacology
Vasopressors and Inotropes
 • Norepinephrine - Levophed - "Levo" - Generally thought of as the first
Vasopressors and ... Adrenalin - "Epi" - ACLS ... @EmmGeezee #Vasopressors ... criticalcare #summary #comparison ... #table #pharmacology
Cardiac Event Monitors
 • Holter Monitor - Records every heart beat for 24-48 hours
 • Loop/Event
Cardiac Event Monitors ... StanfordChiefs #Cardiac ... Monitors #heart #cardiology ... telemetry #devices #comparison ... #table
Side Effects of Atypical and Typical Antipsychotics - Comparison Table
Atypical antipsychotics: Risperidone, Quetiapine, Olanzapine, Amisulpride, Ziprasidone
Antipsychotics - Comparison ... Table Atypical ... are common to all ... risk of sudden cardiac ... #Pharmacology #
Cardiac Event Monitoring Devices - Compared
Ambulatory ECG (Hotter):
 • Advantages: Continuous recording, records asx events, all
Cardiac Event Monitoring ... recording, records asx events ... , all (most) ECG ... Monitoring #Devices #Comparison ... #cardiology #management
Cardiac Valve Replacement - Anticoagulation INR Targets and Antiplatelet by Valve Type

Bioprosthetic valves require at least
Cardiac Valve Replacement ... valves since these agents ... valve (2017 AHA/ACC ... #Management #Cardiology ... #Target #DOAC #Table
Intraoperative Anaphylaxis - Guidelines for Crises in Anaesthesia
• Unexplained hypotension
• Unexplained bronchospasm (wheeze may be absent
• Unexpected cardiac ... surgery. ❷ Call for cardiac ... pack. ❸ Remove all ... give alternate vasopressor ... as patient is stable