13 results
Adrenal Insufficiency Algorithm - Cosyntropin Stimulation Test
T-1m: Baseline cortisol drawn
T0: 250 µg cosyntropin given IV
T30m: Repeat
Adrenal Insufficiency ... Algorithm - Cosyntropin ... Stimulation Test ... level drawn BCM IM ... #Stimulation #endocrinology
Adrenal Insufficiency Diagnosis Algorithm
Test 1: Baseline AM Cortisol 
 - Beware of major normal value
 -
Adrenal Insufficiency ... Diagnosis Algorithm ... Test 1: Baseline ... response BCM IM ... #endocrinology
Approach to Thyroid Function Tests in the Evaluation of Hyperthyroidism
 • Low TSH, Low normal T4
Thyroid Function Tests ... in the Evaluation ... • Low TSH, normal ... Hyperthyroidism #algorithm ... #diagnosis #endocrinology
Adrenal Insufficiency Diagnosis Algorithm - Evaluation of HPA Axis Response to ACTH

Early am cortisol < 3
Adrenal Insufficiency ... Diagnosis Algorithm ... - Evaluation of ... Standard Stim test ... #Endocrinology
Flowchart guide to interpreting thyroid function tests. Visit gramproject.com for more medical diagrams, tables and flowcharts
thyroid function tests ... #differential #algorithm ... #thyroid #endocrinology ... #TSH
Adrenal Insufficiency Diagnosis Algorithm
Clinical features: 
 - Weight loss, anorexia, Weakness, fatigue, GI distress
 - Hypotension,
Diagnosis Algorithm ... findings (see algorithm ... cosyntropin stimulation test ... interact with stim test ... Stimulation #StimTest #Endocrinology
Adrenal Insufficiency Differential Diagnosis Algorithm
Clinical suspicion: Weakness, fatigue, nausea, musculoskeletal pain, dizziness, volume depletion, abdominal pain,
Adrenal Insufficiency ... Differential Diagnosis Algorithm ... ACTH) stimulation test ... Differential #Diagnosis #Algorithm ... #endocrinology
Hyperthyroidism (low TSH, High T4/T3) - Diagnostic Algorithm

Radioactive iodine scan – get if concern for nodular
Hyperthyroidism (low TSH ... ) - Diagnostic Algorithm ... Check pregnancy test ... Hyperthyroid #Diagnosis #Algorithm ... #Workup #Endocrinology
Primary Adrenal Insufficiency:
 • ACTH stimulation test - Synthetic ACTH does not stimulate cortisol secretion because
Primary Adrenal Insufficiency ... primary adrenal insufficiency ... Secondary Adrenal Insufficiency ... #Evaluation #laboratory ... diagnosis #testing #endocrinology
Algorithm for the diagnosis of adrenal insufficiency (AI). The standard cosyntropin stimulation test (CST) may be
Algorithm for the ... diagnosis of adrenal insufficiency ... cosyntropin stimulation test ... the first-line test ... for evaluation