POCUS for Small Bowel Obstruction - Visual Abstract What is the accuracy of point of care ultrasound compared to CT for the diagnosis of SBO? Sensitivity - 88% Specificity - 54% LR+ 1.92 LR- 0.22 Study: https://pubmed.ncbi.nlm.nih.gov/307 Full UltrasoundGEL Podcast Episode: https://podcasts.apple.com/us/podca #SBO #SmallBowel #Obstruction #POCUS #diagnosis #ebm #visualabstract