Right Ventricular Size and Measurements on POCUS Echocardiogram - Proximal Outflow Tract (PLAX View) >30 mm abnormal (normal range 20-30 mm) - Distal outflow tract (PSAX view) >27 mm abnormal (normal range 17-27 mm) - Proximal outflow tract (PSAX view) >35 mm abnormal (normal range 21-35 mm) - Apical RV mid-level, abnormal >35 mm (normal range 19-35) - Apical RV at base, abnormal >41 mm (normal range 25-41 mm) Abhilash Koratala MD - NephroPOCUS @NephroP #RV #Right #Ventricular #Size #Measurements #POCUS #Echocardiogram #diagnosis #cardiology