32 results
Accuracy of abdominal ultrasound for the diagnosis of small bowel obstruction in the emergency department

https://www.ncbi.nlm.nih.gov/pubmed/30181794

Our data
Accuracy of abdominal ... ultrasound for ... demonstrated a sensitivity ... CT, and a sensitivity ... POCUS #Diagnosis #Accuracy
Small Bowel Obstruction Testing Accuracy
#Diagnosis #SBO #Testing #Accuracy #Sensitivity #Specificity #KUB #AbdominalXRay #CT #POCUS #LikelihoodRatio #Comparison
Obstruction Testing Accuracy ... #SBO #Testing #Accuracy ... #Sensitivity #Specificity ... #KUB #AbdominalXRay ... LikelihoodRatio #Comparison #Table
Sensitivity and Specificity of KUB compared to CT for Bowel Obstruction, Urolithiasis, Appendicitis, Pyelonephritis, Pancreatitis, Diverticulitis
Comparison
Sensitivity and ... Specificity of KUB ... pubmed/12355000 #KUB ... AbdominalXRay #Sensitivity ... #Specificty #Accuracy
Cholecystitis Diagnostic Test Characteristics  

Sensitivity, Specificity and Likelihood Ratios of Labs, Physical Exam findings, and
Characteristics Sensitivity ... Characteristics #Table ... #Sensitivity #Specificity ... LikelihoodRatio #Accuracy
Imaging Modalities for Renal Calculus

AXR. KUB
 - Good far calcium-containing stones useful when limited radiation dose
KUB - Good far ... non-invasive - High sensitivity ... Rapid. highly accurate ... obstruction - Able ... causes of flank or abdominal
POCUS for diagnosing the source of Sepsis - Visual Abstract
What is the accuracy of using point-of-care
Abstract What is the accuracy ... point-of-care ultrasound ... - POCUS: Sensitivity ... Clinical Standard: Sensitivity ... source #POCUS #ultrasound
Emergency physician interpretation of point-of-care ultrasound for identifying and grading of hydronephrosis in renal colic compared
point-of-care ultrasound ... Hydronephrosis #Comparison #Accuracy ... #Sensitivity #Specificity
POCUS for diagnosis of Aortic Dissection - Visual Abstract
What is the accuracy of point-of-care ultrasound evaluation
Abstract What is the accuracy ... point-of-care ultrasound ... Sensitivity - 86% ... Dissection #POCUS #ultrasound
X-ray limitations
It’s important to know the limitations of X-rays so we can correctly interpret them in
Point Of Care UltraSound ... Radiology #ChestXRay #KUB ... #CXR #Sensitivity
Lung POCUS for Diagnosis of CHF - Visual Abstract
What is the accuracy of combined Lung Ultrasound
Abstract What is the accuracy ... combined Lung Ultrasound ... Lung Ultrasound: ... - AUC: 94.5 - Sensitivity ... - AUC: 87.2 - Sensitivity