Oxygen delivery & ABG interpretation made easier with this simple colour-coded table. Please share, and print
Oxygen delivery ... with this simple colour-coded ... table. ... #Devices #Interfaces ... #FiO2 #NonRebreather
Mask Oxygen Delivery Devices

Simple Mask aka Hudson's Mask:
 • Flow 6-10 LPM
 • FiO2 35-50%
Face Tent:
Devices Simple ... A venturi mask uses ... venturi valves are color ... coded; each is ... #Devices #management
Oxygen Delivery by Device

Nasal Cannula 
• Indicated for low-flow, low-percentage supplemental oxygen. 
• Flow rate of
by Device Nasal ... high percentage FiO ... retention of exhaled gases ... • Uses either ... #Equipment #Devices
Oxygen Delivery Systems and Approximate FiO2:
#Management #SupplementalO2 #Oxygen #Delivery #Devices #Interface #FiO2 #NonRebreather #HFNC #NasalCannula #Simple
Oxygen Delivery ... and Approximate FiO2 ... #Devices #Interface ... #FiO2 #NonRebreather ... FaceMask #Venture #Table
Oxygen Delivery Devices - Comparison
Low Flow:
 • Nasal cannula (1-6L, 24-40% FiO2)
 • Face mask (5-10L,
Oxygen Delivery ... Devices - Comparison ... iMedEducation #Oxygen #Delivery ... #Devices #Comparison ... #table #pulmonary
Warfarin Tablet Colors - Strengths Mnemonic

Did you know that the tablets are color-coded? Here’s a mnemonic
Warfarin Tablet ... the tablets are color-coded ... the 9 different tablet ... will not be the case ... #Warfarin #Tablet
Hypotension - Guidelines for Crises in Anaesthesia

Hypotension is commonly due to unnecessarily deep anaesthesia, the autonomic
adequate oxygen delivery ... Adequate oxygen delivery ... check measured FiO2 ... position of airway device ... airway AND airway device
Increased Airway Pressure - Guidelines for Crises in Anaesthesia

Using these steps from start to end should
❶Adequate oxygen delivery ... check measured FiO2 ... position of airway device ... Confirm airway device ... whether airway device
Intraoperative Hypertension - Guidelines for Crises in Anaesthesia
Hypertension is most commonly due to inappropriate depth of
adequate oxygen delivery ... Adequate oxygen delivery ... check measured FiO2 ... Confirm airway device ... hypercarbia as causes
Cardiac Arrest - Guidelines for Crises in Anaesthesia

The probable cause is one or more of: something
The probable cause ... Adequate oxygen delivery ... check measured FiO2 ... position of airway device ... Confirm airway device