16 results
Syncope Diagnostic Testing and Evaluation: Cost Effectiveness
Frequency obtained - Abnormal findings - Helped determine etiology of
Syncope Diagnostic Testing ... - Cost per test ... enzymes, Head CT ... diagnosis #workup #testing ... #table #comparison
Small Bowel Obstruction Testing Accuracy
#Diagnosis #SBO #Testing #Accuracy #Sensitivity #Specificity #KUB #AbdominalXRay #CT #POCUS #LikelihoodRatio #Comparison
Bowel Obstruction Testing ... #Accuracy #Sensitivity ... AbdominalXRay #CT ... LikelihoodRatio #Comparison ... #Table
Estimated Medical Radiation Doses for 5 Year-Old Child

3-view ankle	0.0015 mSv	1/14th CXRs
2-view chest	0.02 mSv	1 CXRs
Anteroposterior and lateral
Medical Radiation Doses ... Background #Radiation #Doses ... #Nuclear #Comparison ... #Table #Risks # ... Testing #Study #
Radiation Dose to Adults from Common Imaging Examinations
ABDOMINAL REGION
 - Computed Tomography (CT) — Abdomen and
Radiation Dose to ... Background #Radiation #Doses ... #Nuclear #Comparison ... #Table #Risks # ... Testing #Study
Algorithm for the Management of Ventricular Tachycardia Electrical Storm
ES diagnosed (≥ 3 episodes of VT/ICD therapies
Algorithm for the ... Management of Ventricular ... therapies in 24h) Does ... cardioversion Stable ... #Tachycardia #Algorithm
Treatment of Stable Narrow-Complex Tachycardia
Regular Rhythm:
 • Attempt vagal maneuvers
 • Give adenosine 6 milligrams IV
Treatment of Stable ... Repeat 12-milligram dose ... underlying cause #Stable ... Tachycardia #Treatment #management ... #cardiology #algorithm
How much radiation is used in paediatric radiology examinations compared to other exposures?

Estimated dose - Days
Estimated dose - ... Background #Radiation #Doses ... #Nuclear #Comparison ... #Table #Risks # ... Testing #Study #
CA-Bridge Buprenorphine Hospital Quick Start Algorithm - Management of acute opiate withdrawal 
 - Any prescriber
Hospital Quick Start Algorithm ... - Management of ... effective for treating ... If patient is stable ... Buprenorphine #Treatment #Algorithm
Additional Modalities for Workup of GI Bleed (Other than EGD + Colonoscopy)

Pill endoscopy
 • Able to
endoscopy limits, high sensitivity ... Triple-phase CT ... bowel duplication cysts ... Bleed #GIBleed #management ... gastroenterology #table
Performance Characteristics for Colorectal Cancer Screening Tests
Stool/blood-based tests:
 • FIT: 79% sensitivity, 94% specificity for CRC
DNA test: 92% sensitivity ... mortality 26% • CT ... Screening #Tests #comparison ... #table #management ... gastroenterology #CRC #Testing