12 results
Likelihood Ratios of Clinical Features Ruling In Deep Vein Thrombosis
Malignant disease	2.71
History of deep vein thrombosis	2.25
Recent immobilization	1.98
Difference
Obesity 0.85 - EB ... Likelihood #Ratios #DeepVein ... DVT #diagnosis #LRs
Lung POCUS for Diagnosis of CHF - Visual Abstract
What is the accuracy of combined Lung Ultrasound
Lung POCUS for Diagnosis ... Lung Ultrasound (LUS ... + 8.0 - LR- 0.17 ... heart #failure #POCUS ... #diagnosis #ebm
3 Point POCUS for DVT - Visual Abstract
How accurately can emergency physicians diagnose lower extremity DVTs
3 Point POCUS for ... care ultrasound (POCUS ... Specificity - 90% - LR ... + 9.32 - LR- 0.08 ... ultrasound #diagnosis #ebm
POCUS for diagnosis of Diverticulitis - Visual Abstract
What are the test characteristics of point-of-care ultrasonography in
POCUS for diagnosis ... Specificity - 92% LR ... + 30.7 LR- 0.08 ... Diverticulitis #POCUS ... ultrasound #diagnosis #ebm
Electrical Alternans on POCUS Echocardiogram
You dissect the EKG and note low voltage tachycardia with a hint
Electrical Alternans on POCUS ... note low voltage tachycardia ... POCUS ECHO performed ... - MH/CCF/CWRU EM ... Electrical #Alternans #POCUS
POCUS for diagnosis of Wall Motion Abnormalities in Myocardial Infarction - Visual Abstract
Can physicians with limited
POCUS for diagnosis ... • RWMA +LR 11.5, ... +LR 5.4, -LR 0.1 ... echocardiogram #POCUS ... ultrasound #diagnosis #ebm
The value of point-of-care ultrasound for detecting nail bed injury in [the] ED

American Journal of Emergency
(CI 74-100), +LR ... (CI 79-100), -LR ... (CI 91-100), +LR ... Subungual #Fracture #POCUS ... #Ultrasound #EBM
This is a parasternal long axis view of a young patient presenting with 3 days of
ECG with sinus tachycardia ... Michael Macias, EM ... University #Clinical #EM ... #Radiology #POCUS
POCUS for Small Bowel Obstruction - Visual Abstract
What is the accuracy of point of care ultrasound
POCUS for Small ... Specificity - 54% LR ... + 1.92 LR- 0.22 ... #Obstruction #POCUS ... #diagnosis #ebm
Point of Care Ultrasound for Appendicitis - Visual Abstract

Can emergency physicians diagnose appendicitis with high specificity
Specificity 97.9% + LR ... 20.6 - LR 0.58 ... Michael Prats #POCUS ... Specificity #Likelihood #EBM