6 results
Intraosseous (EZ-IO) Access in the Humeral Head of an adult

Rule of 45s:
- 45mm needle
- 45° angle
Access in the Humeral ... head - 45° to anterior ... conscious pt #Management ... #Procedure #Line ... #Placement #Instructions
Resuscitative Hysterotomy - Procedure Instructions
When? ASAP. Within 4 minutes when possible.
Who? Pregnant patient with uterus above
Hysterotomy - Procedure ... Instructions When ... Cardiac Arrest Management ... checklist #obstetrics ... #emergency
EZ-IO® Device Proximal
Humerus Identification
and Insertion Technique

Insertion:
 • Prepare the site by using antiseptic solution per institutional
Device Proximal Humerus ... approximately 45-degrees anterior ... against the bone #Management ... #Procedure #Line ... #Placement #Instructions
Perimortem Hysterotomy Instructions

Do 4 minutes into arrest if uterus above the umbilicus

1. Manage Arrest
 • Compressions,
Perimortem Hysterotomy Instructions ... into arrest if uterus ... #Hysterotomy #Instructions ... #Obstetrics #Emergency ... #management #checklist
Surgical Chest Tube for Unstable Pneumothorax or Hemothorax
PREPARE
 • Landmark: Anterior Axillary Line, 4th or 5th
• Landmark: Anterior ... Sterile gloves & drapes ... #chesttube #placement ... #checklist #procedure ... #instructions #
Percutaneous Dilational Tracheostomy - Procedure Instructions Checklist
Tracheostomy is to establish a definitive surgical opening into the
Tracheostomy - Procedure ... Instructions Checklist ... Sterilize and drape ... anterior neck Landmarks ... #management #procedure