7 results
Accuracy of abdominal ultrasound for the diagnosis of small bowel obstruction in the emergency department

https://www.ncbi.nlm.nih.gov/pubmed/30181794

Our data
demonstrated a sensitivity ... of 93.8% and a specificity ... of 94.3% and specificity ... #Obstruction #SBO ... VisualAbstract #EBM
POCUS Confirmation of CVC Placement - Visual Abstract
How accurate is a single view ultrasound protocol for
POCUS Confirmation ... - Sensitivity - ... 86.8% - Specificity ... simplified-cvc-confirmation ... ultrasound #diagnosis #ebm
Diagnosis Adrenal Insufficiency - Algorithm

Step 1) Screening Test: 6-8AM Cortisol Level
 - Early morning cortisol levels
Insufficiency - Algorithm ... have almost 100% specificity ... for AI (but low sensitivity ... Step 2) Confirmation ... Insufficiency #Algorithm
POCUS Confirmation of Tracheal Intubation - Visual Abstract
How accurate is tracheal ultrasound in determining whether the
POCUS Confirmation ... - Sensitivity - ... 98.9% - Specificity ... 1000421508662 #Confirmation ... neck #diagnosis #ebm
Hunter's Decision Rule (Sensitivity 84%, Specificity 97%), Sternbach's criteria - Need 3 of 10 symptoms: (Sensitivity
Decision Rule (Sensitivity ... 84%, Specificity ... 75%, specificity ... 96%) #Diagnosis #EM ... Syndrome #Hunters #Algorithm
POCUS for Small Bowel Obstruction - Visual Abstract
What is the accuracy of point of care ultrasound
the diagnosis of SBO ... Sensitivity - 88% ... Specificity - 54% ... 1000453623471 #SBO ... POCUS #diagnosis #ebm
The Febrile Infant Step-by-Step Algorithm
This is an algorithm developed by European emergency physicians to identify low-risk
Infant Step-by-Step Algorithm ... This is an algorithm ... pubmed/27382134 Sensitivity ... and specificity ... 46.9% #Diagnosis #EBM