11 results
Cholecystitis Diagnostic Test Characteristics  

Sensitivity, Specificity and Likelihood Ratios of Labs, Physical Exam findings, and
Cholecystitis Diagnostic ... , Specificity and ... Cholecystitis #Testing ... Characteristics #Table ... #Sensitivity #Specificity
Ohle R et al. Clinical Examination for Acute Aortic Dissection: A Systematic Review and Meta-analysis. AEM
Dissection #Aorta #Testing ... Signs #Accuracy #Sensitivity ... #Specificity #SGEM ... #VisualAbstract ... #EBM #Diagnosis
Accuracy of abdominal ultrasound for the diagnosis of small bowel obstruction in the emergency department

https://www.ncbi.nlm.nih.gov/pubmed/30181794

Our data
demonstrated a sensitivity ... of 93.8% and a specificity ... of 94.3% and specificity ... #Accuracy #Testing ... Abdominal #Ultrasound #VisualAbstract
Diagnostic algorithm for the workup of hypercalcemia. The diagnostic workup for patients presenting with hypercalcemia rests
Diagnostic algorithm ... The diagnostic workup ... value of 0.0115, sensitivity ... ) was 0.80 and specificity ... Thus, further testing
Commonly Used Diagnostic Tests for Celiac Disease

Tissue transglutaminase (tTG) IgA antibodies
 - Most reliable noninvasive test
Commonly Used Diagnostic ... and specificity ... and specificity ... Celiac #Disease #Testing ... #Workup #Table
COVID19 Testing - PCR vs CT - Sensitivity and Specificity

Original Data via https://pubs.rsna.org/doi/full/10.1148/radiol.2020200642

Admission laboratory patterns in
COVID19 Testing ... - PCR vs CT - Sensitivity ... and Specificity ... #Diagnosis #Coronavirus ... #VisualAbstract
Lung POCUS for Diagnosis of CHF - Visual Abstract
What is the accuracy of combined Lung Ultrasound
a traditional work ... - AUC: 94.5 - Sensitivity ... - 93.5 - Specificity ... - 85.0 - Specificity ... #ebm #visualabstract
Small Bowel Obstruction Testing Accuracy
#Diagnosis #SBO #Testing #Accuracy #Sensitivity #Specificity #KUB #AbdominalXRay #CT #POCUS #LikelihoodRatio #Comparison
Accuracy #Diagnosis ... #SBO #Testing # ... Accuracy #Sensitivity ... #Specificity #KUB ... LikelihoodRatio #Comparison #Table
Diagnosis Adrenal Insufficiency - Algorithm

Step 1) Screening Test: 6-8AM Cortisol Level
 - Early morning cortisol levels
Insufficiency - Algorithm ... have almost 100% specificity ... for AI (but low sensitivity ... require Cosyntropin testing ... Insufficiency #Algorithm
Celiac Disease - Diagnosis Algorithm
IgA TTG has high sensitivity and specificity of ~ 98% and is
Algorithm IgA ... TTG has high sensitivity ... and specificity ... pts need further testing ... #workup