29 results
Intraoperative Hypertension - Guidelines for Crises in Anaesthesia
Hypertension is most commonly due to inappropriate depth of
adequate oxygen delivery ... Adequate oxygen delivery ... check measured FiO2 ... Intraoperative #Checklist ... Diagnosis #Management #Workup
Hypotension - Guidelines for Crises in Anaesthesia

Hypotension is commonly due to unnecessarily deep anaesthesia, the autonomic
adequate oxygen delivery ... Adequate oxygen delivery ... check measured FiO2 ... Intraoperative #Checklist ... Diagnosis #Management #Workup
Intraoperative  Bradycardia - Guidelines for Crises in Anaesthesia
Bradycardia in theatre should not be treated as
Adequate oxygen delivery ... check measured FiO2 ... Confirm airway device ... Intraoperative #Checklist ... Diagnosis #Management #Workup
Intraoperative Tachycardia - Guidelines for Crises in Anaesthesia
Tachycardia in theatre is often due to inadequate depth
Adequate oxygen delivery ... check measured FiO2 ... Confirm airway device ... Intraoperative #Checklist ... Diagnosis #Management #Workup
Increased Airway Pressure - Guidelines for Crises in Anaesthesia

Using these steps from start to end should
❶Adequate oxygen delivery ... check measured FiO2 ... Confirm airway device ... Intraoperative #Checklist ... Diagnosis #Management #Workup
Cardiac Arrest - Guidelines for Crises in Anaesthesia

The probable cause is one or more of: something
Adequate oxygen delivery ... check measured FiO2 ... position of airway device ... Confirm airway device ... Diagnosis #Management #Workup
Oxygen Delivery by Device

Nasal Cannula 
• Indicated for low-flow, low-percentage supplemental oxygen. 
• Flow rate of
by Device Nasal ... high percentage FiO ... desired FiO ... #FiO2 #Pulmonary ... #Equipment #Devices
Key Basic Plan - Guidelines for Crises in Anaesthesia

This Key Basic Plan will detect and identify
Adequate oxygen delivery ... check measured FiO2 ... Confirm airway device ... anaesthesia #Basics #Checklist ... Diagnosis #Management #Workup
Intraoperative Hypoxia / Desaturation / Cyanosis - Guidelines for Crises in Anaesthesia
Using these steps from start
Adequate oxygen delivery ... check measured FiO2 ... Intraoperative #Checklist ... #Diagnosis #Workup ... #Management #Workup
Oxygen Delivery Systems and Approximate FiO2:
#Management #SupplementalO2 #Oxygen #Delivery #Devices #Interface #FiO2 #NonRebreather #HFNC #NasalCannula #Simple
Oxygen Delivery ... and Approximate FiO2 ... SupplementalO2 #Oxygen #Delivery ... #Devices #Interface ... #FiO2 #NonRebreather