164 results
Oxygen Delivery Systems and Approximate FiO2:
#Management #SupplementalO2 #Oxygen #Delivery #Devices #Interface #FiO2 #NonRebreather #HFNC #NasalCannula #Simple
Oxygen Delivery ... and Approximate FiO2 ... : #Management # ... #Delivery #Devices ... #Interface #FiO2
Oxygen Delivery Systems
Nasal Cannula:
 • Flow: 1 - 6 L/min
 • FiO2: 25 - 40% (-4%/L
Oxygen Delivery ... : 40 - 60% Device ... rishikumarmd #Oxygen ... respiratory #support #devices ... #management #pulmonary
Oxygen Delivery by Device

Nasal Cannula 
• Indicated for low-flow, low-percentage supplemental oxygen. 
• Flow rate of
by Device Nasal ... high percentage FiO ... #FiO2 #Pulmonary ... #Equipment #Devices ... #Management
Mask Oxygen Delivery Devices

Simple Mask aka Hudson's Mask:
 • Flow 6-10 LPM
 • FiO2 35-50%
Face Tent:
Mask Oxygen Delivery ... Devices Simple ... small valve to mix oxygen ... #Delivery #Devices ... #management #pulmonary
Oxygen Delivery Devices
1. Flow is a variable describing the movement of a volume of gas over
Oxygen Delivery ... Oxygen delivery ... resulting in an FiO2 ... more predictable FiO2 ... Flow #Comparison #management
Oxygen delivery & ABG interpretation made easier with this simple colour-coded table. Please share, and print
Oxygen delivery ... Birks @BirksMD #Management ... SupplementalO2 #Oxygen ... #Delivery #Devices ... #Interfaces #FiO2
Nasal Oxygen Delivery Devices
Nasal cannula can be used to deliver supplemental O2. Conventional nasal cannula are
Nasal Oxygen Delivery ... Devices Nasal ... nickmmark #Nasal #Oxygen ... #Delivery #Devices ... #management #pulmonary
Intraoperative Hypertension - Guidelines for Crises in Anaesthesia
Hypertension is most commonly due to inappropriate depth of
problem in adequate oxygen ... check measured FiO2 ... position of airway device ... Confirm airway device ... Checklist #Diagnosis #Management
Hypotension - Guidelines for Crises in Anaesthesia

Hypotension is commonly due to unnecessarily deep anaesthesia, the autonomic
❶ Adequate oxygen ... check measured FiO2 ... position of airway device ... airway AND airway device ... Checklist #Diagnosis #Management
Increased Airway Pressure - Guidelines for Crises in Anaesthesia

Using these steps from start to end should
. ❶Adequate oxygen ... AND give 100% oxygen ... check measured FiO2 ... Confirm airway device ... Checklist #Diagnosis #Management