Oxygen Delivery Systems
Nasal Cannula:
 • Flow: 1 - 6 L/min
 • FiO2: 25 - 40% (-4%/L
- 6 L/min • FiO2 ... of flow) Face Mask ... : 40 - 60% Device ... ~40% Venturi Mask ... respiratory #support #devices
Mask Oxygen Delivery Devices

Simple Mask aka Hudson's Mask:
 • Flow 6-10 LPM
 • FiO2 35-50%
Face Tent:
Devices Simple ... 6-10 LPM • FiO2 ... 10-15 LPM • FiO2 ... 10-15 LPM • FiO2 ... Oxygen #Delivery #Devices
Oxygen Delivery by Device

Nasal Cannula 
• Indicated for low-flow, low-percentage supplemental oxygen. 
• Flow rate of
Oxygen Delivery by Device ... high percentage FiO ... set to desired FiO2 ... deliver desired FiO ... Pulmonary #Equipment #Devices
Oxygen Delivery Devices - Comparison
Low Flow:
 • Nasal cannula (1-6L, 24-40% FiO2)
 • Face mask (5-10L,
Oxygen Delivery Devices ... ) • Face mask ( ... Face tent/shovel mask ... ) • Venturi mask ... Oxygen #Delivery #Devices
Oxygen Delivery Devices
1. Flow is a variable describing the movement of a volume of gas over
Oxygen Delivery Devices ... Variable devices ... resulting in an FiO2 ... more predictable FiO2 ... NRB) • Venturi Mask
Intraoperative Hypertension - Guidelines for Crises in Anaesthesia
Hypertension is most commonly due to inappropriate depth of
for Crises in Anaesthesia ... check measured FiO2 ... position of airway device ... Confirm airway device ... Anesthesiology #Anesthesia
Intraoperative Tachycardia - Guidelines for Crises in Anaesthesia
Tachycardia in theatre is often due to inadequate depth
for Crises in Anaesthesia ... check measured FiO2 ... position of airway device ... Confirm airway device ... Anesthesiology #Anesthesia
Intraoperative  Bradycardia - Guidelines for Crises in Anaesthesia
Bradycardia in theatre should not be treated as
for Crises in Anaesthesia ... check measured FiO2 ... position of airway device ... Confirm airway device ... Anesthesiology #Anesthesia
Intraoperative Sepsis - Guidelines for Crises in Anaesthesia

Severe sepsis (hypotension persisting after initial fluid challenge of
for Crises in Anaesthesia ... problem. ❷ Increase FiO2 ... whether indwelling devices ... for crises in anaesthesia ... Anesthesiology #Anesthesia
Hypotension - Guidelines for Crises in Anaesthesia

Hypotension is commonly due to unnecessarily deep anaesthesia, the autonomic
for Crises in Anaesthesia ... check measured FiO2 ... position of airway device ... airway AND airway device ... Anesthesiology #Anesthesia