Intraoperative Mains Oxygen Supply Failure - Guidelines for Crises in Anaesthesia

Complete failure of wall or pendant
Intraoperative Mains ... Oxygen Supply Failure ... lowest possible FiO2 ... • Check FiO2 ... Anesthesiology #Anesthesia #Intraoperative
Intraoperative Hypertension - Guidelines for Crises in Anaesthesia
Hypertension is most commonly due to inappropriate depth of
Intraoperative Hypertension ... problem in adequate oxygen ... stimulus. ❷ Adequate oxygen ... check measured FiO2 ... Anesthesiology #Anesthesia #Intraoperative
Hypotension - Guidelines for Crises in Anaesthesia

Hypotension is commonly due to unnecessarily deep anaesthesia, the autonomic
problem in adequate oxygen ... ❶ Adequate oxygen ... AND give 100% oxygen ... check measured FiO2 ... Anesthesiology #Anesthesia #Intraoperative
Intraoperative  Bradycardia - Guidelines for Crises in Anaesthesia
Bradycardia in theatre should not be treated as
Intraoperative ... B. ❷ Adequate oxygen ... check measured FiO2 ... Anesthesiology #Anesthesia #Intraoperative
Intraoperative Tachycardia - Guidelines for Crises in Anaesthesia
Tachycardia in theatre is often due to inadequate depth
Intraoperative Tachycardia ... analgesia. ❷ Adequate oxygen ... check measured FiO2 ... Anesthesiology #Anesthesia #Intraoperative
Increased Airway Pressure - Guidelines for Crises in Anaesthesia

Using these steps from start to end should
. ❶Adequate oxygen ... AND give 100% oxygen ... check measured FiO2 ... Anesthesiology #Anesthesia #Intraoperative
Intraoperative Hypoxia / Desaturation / Cyanosis - Guidelines for Crises in Anaesthesia
Using these steps from start
Intraoperative Hypoxia ... ❶ Adequate oxygen ... AND give 100% oxygen ... check measured FiO2 ... Anesthesiology #Intraoperative
Cardiac Arrest - Guidelines for Crises in Anaesthesia

The probable cause is one or more of: something
). ❷ Adequate oxygen ... flow, give 100% oxygen ... check measured FiO2 ... Anesthesiology #Anesthesia #Intraoperative
Mask Oxygen Delivery Devices

Simple Mask aka Hudson's Mask:
 • Flow 6-10 LPM
 • FiO2 35-50%
Face Tent:
Mask Oxygen Delivery ... Flow 6-10 LPM • FiO2 ... small valve to mix oxygen ... increases delivered oxygen ... nickmmark #Mask #Oxygen
Oxygen Delivery by Device

Nasal Cannula 
• Indicated for low-flow, low-percentage supplemental oxygen. 
• Flow rate of
Oxygen Delivery ... high percentage FiO ... set to desired FiO2 ... deliver desired FiO ... #FiO2 #Pulmonary