11 results
First-line therapies for Asthma, Asthma-COPD Overlap and COPD

The diagnosis of COPD, asthma, and ACO initially requires
initially requires an evaluation ... bronchodilator test ... , and sensitivity ... summary of the differential ... #Differences #Algorithm
Helicobacter Pylori Testing  Methods - Sensitivity and Specificity

Serology - 85% - 79% - Does not
Methods - Sensitivity ... Urea breath test ... BEST first line test ... #Laboratory #Diagnosis ... #Accuracy
Abnormal liver function tests algorithm.
 This figure details the initial response to abnormal liver blood tests.
algorithm. ... indicate the initial evaluation ... history alongside evaluation ... decision for repeat testing ... Liver #Enzymes #Differential
Diagnostic algorithm for the workup of hypercalcemia. The diagnostic workup for patients presenting with hypercalcemia rests
Diagnostic algorithm ... hypercalcemia rests ... value of 0.0115, sensitivity ... Thus, further testing ... Hypercalcemia #Workup #Differential
Diagnosis Adrenal Insufficiency - Algorithm

Step 1) Screening Test: 6-8AM Cortisol Level
 - Early morning cortisol levels
Insufficiency - Algorithm ... for AI (but low sensitivity ... require Cosyntropin testing ... Step 3) Differentiate ... Insufficiency #Algorithm
Diarrhea Workup and Management Algorithm in Transplant Patients
First Tier Microbiologic-Testing:
1. C. difficile PCR (Stool)
2. CMV qPCR
and Management Algorithm ... Ova and Parasite evaluation ... Breath test for ... Workup #Management #Algorithm ... Transplant #diagnosis #differential
Causes of Primary Amenorrhea - Differential Diagnosis Algorithm
No onset of menarche by age 16 with secondary
Primary Amenorrhea - Differential ... Diagnosis Algorithm ... • Vanishing Testes ... Functional (e.g. eating ... #Diagnosis #Algorithm
Causes of Inaccurate Fecal Occult Blood Test Results 

False Positive gFOBT:
Ingestion of nonhuman heme (eg, meat
Fecal Occult Blood Test ... #OccultBlood #Testing ... #Laboratory #FalsePositive ... FalseNegative #Diagnosis #Differential ... #Accuracy #Inaccurate
1,3-Beta-D-Glucan and Galactomannan Testing Sensitivity Specificity and False Positives
1,3-Beta-D-Glucan
 • Cell wall component of many fungi
Galactomannan Testing ... the use of this test ... in BAL does not differentiate ... Galactomannan #Fungal #Testing ... FalsePositives #Laboratory
Antibiotic Susceptibility Testing Methods
1) Kirby Bauer Disk Diffusion: disks impregnanted w/ Abx → circular gradient →
Susceptibility Testing ... Gradient diffusion (E test ... concentrations + algorithms ... #Antibiotic #Sensitivity ... #laboratory #microbiology