16 results
Reference Laboratory Values - Fishbone Shorthand
Complete Blood Count (CBC), Basic Metabolic Panel (BMP), Liver Function Tests
Reference Laboratory ... Panel (BMP), Liver Function ... Tests (LFTs) and ... #Values #Labs # ... Reference #Normal
Algorithm for Investigation of Abnormal Coagulation Tests
- Prolonged PT
- Prolonged aPTT and Prolonged PT
- Prolonged aPTT

Dr.
Algorithm for Investigation ... of Abnormal Coagulation ... Tests - Prolonged ... #APTT #Laboratory ... Hematology #Diagnosis #Workup
Pulmonary Function Tests (PFTs) - Interpretation Algorithm
 • Normal
 • Pulmonary Hypertension, Anemia, Carboxyhemoglobinemia
 • Chest
Pulmonary Function ... Tests (PFTs) - ... Interpretation Algorithm ... • Normal • ... #Algorithm #diagnosis
Causes of Thrombocytopenia and Platelet Disorders - Differential Diagnosis and Workup
History:
 - Prior platelet count, family
Diagnosis and Workup ... K), H. pylori test ... country), thyroid function ... test, ANA (e.g. ... #Workup #hematology
Liver Function Tests (LFTs) - Normal Values and Interpretation

Alanine aminotransferase (ALT/SGPT) - Liver, cardiac & skeletal
Liver Function Tests ... (LFTs) - Normal ... Values and Interpretation ... prothrombin time across labs ... #Tests #LFTs #Laboratory
Approach to Thyroid Function Tests in the Evaluation of Hyperthyroidism
 • Low TSH, Low normal T4
Approach to Thyroid Function ... Tests in the Evaluation ... Hyperthyroidism: Work-up ... Can repeat labs ... Hyperthyroidism #algorithm
Causes of Anemia with elevated Mean Corpuscular Volume (MCV) - Differential Diagnosis Algorithm
Normal Blood Smear
 •
Causes of Anemia ... Liver Function ... Tests • Rule ... Liver Function ... Tests • Liver
Approach to Thrombotic Microangiopathy (TMA) - Differential Diagnosis and Management Algorithm

Suspected TMA: Unexplained thrombocytopenia + MAHA
and Management Algorithm ... ±AKI Initial labs ... hemosiderin, Hepatic function ... Direct antiglobulin test ... hemosiderin • PT/aPTT normal
Primary Adrenal Insufficiency:
 • ACTH stimulation test - Synthetic ACTH does not stimulate cortisol secretion because
ACTH stimulation test ... CRH stimulation test ... - Serum tests that ... Insufficiency #Evaluation #laboratory ... endocrinology #workup
Major neurocognitive disorders (MNCD): Diagnosis and workup 

1) Clinical diagnosis Cognitive impairment + loss of autonomy
2)
deficiency, ... laboratory ... tests + imaging ... Alzheimer - 1st cause ... impaired executive functions ... Dementia - 2nd cause