26 results
Practical Approach to Grading Diastolic Dysfunction

#Diagnosis #Cardiology #Diastolic #Diastology #Dysfunction #Grading #Classification #Grades #Criteria #Algorithm #Assessment
Practical Approach to Grading ... Diastolic Dysfunction ... #Diagnosis #Cardiology ... #Grading #Classification ... Grades #Criteria #Algorithm
Cervical Central Canal and Neural Foraminal Stenosis Grading

Cervical Central Canal Stenosis Grading
 - Normal - No
- Normal - No ... Neural #Foraminal #Spinal ... #Spine #Report ... #Classification ... #Diagnosis #Radiology
Lumbar Neural Foraminal Stenosis Grading 
  - Normal - No fat effacement, Keyhole appearance
Foraminal Stenosis Grading ... - Normal - ... #Stenosis #Spine ... #Classification ... Neural #Foraminal #Diagnosis
Lumbar Central Canal Stenosis Grading 
  - Normal - No CSF effacement 
  -
Canal Stenosis Grading ... - Normal - ... #Stenosis #Spine ... #Classification ... #Diagnosis #Radiology
Algorithm for Diagnosing Diastolic Dysfunction With Doppler Echocardiography
 1. Determine the age of the patient
Algorithm for Diagnosing ... Diastolic Dysfunction ... pressure (LVFP): #Algorithm ... Echocardiography #Cardiology #Diagnosis ... #Grading #Classification
Diastolic Function Grading - Schematic diastolic filling patterns

I: impaired relaxation, II: moderate diastolic dysfunction (pseudonormal), III:
Diastolic Function Grading ... moderate diastolic dysfunction ... flow progression, LA ... #Diagnosis #Cardiology ... #Grading #Classification
Lumbar stenosis guide we created to implement consistent radiology reporting across our multi-hospital network. 
Lumbar Central
- Normal - ... - Normal - ... #Stenosis #Spine ... #Classification ... Central #Foraminal #Diagnosis
Diastolic Dysfunction Grading - Echocardiography
Grade 0  (Normal):
 • E/A >0.8, e’ > 8 cm/s, E/e’
Diastolic Dysfunction ... Grading - Echocardiography ... Grade 0 (Normal ... #Grading #Echocardiography ... echocardiogram #grades #diagnosis
Severity of Aortic Stenosis in Adults 
Current ACC/AHA guidelines recommend cut-off values for Doppler-echocardiographic measurements of
recommend cut-off values ... follows: aortic valve ... with impaired and normal ... #Diagnosis #Cardiology ... AorticStenosis #Classification
Mitral Valve Regurgitation - Carpentier Classification
Type I - Normal Leaflet Motion
   - Type la
Mitral Valve Regurgitation ... - Carpentier Classification ... Type I - Normal ... #Carpentier #Classification ... Regurgitation #MVR #diagnosis