10 results
Ohle R et al. Clinical Examination for Acute Aortic Dissection: A Systematic Review and Meta-analysis. AEM
#Testing #Symptoms ... Signs #Accuracy #Sensitivity ... #Specificity #SGEM ... #VisualAbstract ... #EBM #Diagnosis
Emergency physician interpretation of point-of-care ultrasound for identifying and grading of hydronephrosis in renal colic compared
pubmed/29663580 #EBM ... #VisualAbstract ... Hydronephrosis #Comparison ... #Accuracy #Sensitivity ... #Specificity #Testing
POCUS for diagnosis of Aortic Dissection - Visual Abstract
What is the accuracy of point-of-care ultrasound evaluation
for diagnosis of Aortic ... Sensitivity - 86% ... Specificity - 100% ... ultrasound #diagnosis #ebm ... #visualabstract
Accuracy of abdominal ultrasound for the diagnosis of small bowel obstruction in the emergency department

https://www.ncbi.nlm.nih.gov/pubmed/30181794

Our data
demonstrated a sensitivity ... of 93.8% and a specificity ... Diagnosis #Accuracy #Testing ... Abdominal #Ultrasound #VisualAbstract ... #EBM
COVID19 Testing - PCR vs CT - Sensitivity and Specificity

Original Data via https://pubs.rsna.org/doi/full/10.1148/radiol.2020200642

Admission laboratory patterns in
COVID19 Testing ... - PCR vs CT - Sensitivity ... and Specificity ... #Coronavirus #VisualAbstract ... #EBM
Small Bowel Obstruction Testing Accuracy
#Diagnosis #SBO #Testing #Accuracy #Sensitivity #Specificity #KUB #AbdominalXRay #CT #POCUS #LikelihoodRatio #Comparison
Bowel Obstruction Testing ... #Accuracy #Sensitivity ... #Specificity #KUB ... LikelihoodRatio #Comparison ... #Table
Comparison of Syncope Rules 

#EBM #Diagnosis #Cardiology #Comparison #Table #Syncope #Rules #SanFrancisco #OESIL #Boston #Rose #ALiEM
Comparison of Syncope ... Rules #EBM # ... #Table #Syncope ... #Rose #ALiEM #Sensitivity ... #Specificity
The value of point-of-care ultrasound for detecting nail bed injury in [the] ED

American Journal of Emergency
POCUS #Ultrasound #EBM ... #VisualAbstract ... #Sensitivity #Specificity ... #Testing
Performance Characteristics for Colorectal Cancer Screening Tests
Stool/blood-based tests:
 • FIT: 79% sensitivity, 94% specificity for CRC
, 94% specificity ... , 87% specificity ... Screening #Tests #comparison ... #table #management ... gastroenterology #CRC #Testing
ACA Colorectal Cancer Screening Guidelines

When to Screen?
When to Stop?
Family History

Performance Characteristics for Colorectal Cancer Screening Tests
Stool/blood-based
, 94% specificity ... , 87% specificity ... Indications #Tests #comparison ... #table #management ... gastroenterology #CRC #Testing