20 results
POCUS Reference Measurements
 • Gallbladder
 • Urinary Bladder
 • GI Tract
 • Pregnancy
 • Optic Nerve
Measurements • ... • Aorta • Cardiac ... #Reference #Measurements ... #Ultrasound #Echocardiogram ... #Diagnosis
POCUS - Measuring Cardiac Output
1) Calculate LVOT Area
2) Calculate LVOT VTI
3) Calculate Cardiac Output

SV = (LVOT
POCUS - Measuring ... Cardiac Output ... #Echocardiogram ... #Measurement #cardiology ... #diagnosis
Right Heart Catheterization Cheat Sheet: Interpretation of Pressures and Waveforms 
Direct measurements
 ● Central venous pressure
Waveforms Direct measurements ... pressure (PCWP) ● Cardiac ... SvO2) Indirect measurements ... PCWP]/CO) ● Cardiac ... Interpretation #Diagnosis
Pulmonary Arterial Catheterization – Use and Interpretation:
-Pulmonary arterial catheterization (PAC) has never been shown to improve
However, when the diagnosis ... mixed, hemodynamic measurements ... output (ie, cardiac ... pressure) -right atrial ... #Diagnosis #PACatheter
POCUS Pearls for Tamponade
- Pericardial Effusion
- Diastolic Right Ventricular Collapse
- Systolic Right Atrial Collapse
- Plethoric Inferior
POCUS Pearls for ... Systolic Right Atrial ... @SAlerhand #Cardiac ... #Diagnosis #Evaluation ... Cardiology #Effusion #Echocardiogram
Arterial Lines & Waveforms
Arterial lines permit continuous invasive blood pressure measurement, frequent arterial blood sampling, and
blood pressure measurement ... used to estimate cardiac ... pulses; seen in low cardiac ... #artlines #diagnosis ... #calibration #criticalcare
An Algorithm for the Evaluation and Management of Cardiac Arrest with Ultrasonography

- Dr. Tom Fadial https://twitter.com/thame

#CardiacArrest
Evaluation and Management ... of Cardiac Arrest ... CardiacArrest #Algorithm #POCUS ... #Evaluation #Diagnosis ... #CriticalCare
Echocardiography
Right ventricular function can be assessed using several methods and echocardiography is generally the first‐line tool
#Diagnosis #Cardiology ... #POCUS #Echocardiogram ... RVDysfunction #Measurements
Capnography
Measurement of exhaled carbon dioxide can be used to confirm ETT placement, for safer procedural sedation,
Capnography Measurement ... and to monitor cardiac ... CO2 • PaCO2 - Arterial ... transplant • Cardiac ... waveforms #patterns #diagnosis
Fluid Responsiveness and Fluid Tolerance Testing - OnePager Summary
Fluid resuscitation can be beneficial when required or
Thermodilution measurement ... facilitating repeat measurements ... analogous to PPV measurement ... Tolerance #testing #diagnosis ... #criticalcare #