60 results
Medial Meniscus Bucket Handle Tear - MSK Radiology
Imaging Findings:
 • Truncation of the medial meniscus on
Handle Tear - MSK ... Radiology Imaging ... Case description ... DrvonBorstel #Medial ... #diagnosis #msk
Intraoperative Sepsis - Guidelines for Crises in Anaesthesia

Severe sepsis (hypotension persisting after initial fluid challenge of
Intraoperative Sepsis ... Check serial lactates ... Discuss ongoing management ... anaesthesia #Sepsis #Anesthesiology ... #Anesthesia #Intraoperative
Intraoperative Massive Blood Loss - Guidelines for Crises in Anaesthesia
Expected or unexpected major haemorrhage

❶ Call for
Intraoperative Massive ... equipment. ❽ Discuss management ... interventional radiology ... BloodLoss #Hemorrhage #Anesthesiology ... #Anesthesia #Intraoperative
Intraoperative Circulatory Embolus - Guidelines for Crises in Anaesthesia
Causes: thrombus, fat, amniotic fluid, air/gas.
Signs: hypotension, tachycardia,
Intraoperative Circulatory ... in Anaesthesia Causes ... mainstay of initial management ... Embolism #VTE #Anesthesiology ... #Anesthesia #Intraoperative
Pes Anserine Bursitis - MSK Radiology
Imaging Findings:
 • T2-hyperintense fluid-like signal along the medial aspect of
Anserine Bursitis - MSK ... Radiology Imaging ... Case description ... mri #clinical #Radiology ... #diagnosis #msk
Intraoperative Hypertension - Guidelines for Crises in Anaesthesia
Hypertension is most commonly due to inappropriate depth of
Intraoperative Hypertension ... hypercarbia as causes ... TURP syndrome) • Medical ... #Hypertension #Anesthesiology ... Checklist #Diagnosis #Management
Intraoperative Cardiac Ischaemia - Guidelines for Crises in Anaesthesia

If the patient is unconscious, signs of cardiac
Intraoperative Cardiac ... consultation with cardiology ... Ischemia #Ischaemia #Anesthesiology ... #Anesthesia #Intraoperative ... Checklist #Diagnosis #Management
Intraoperative Patient Fire - Guidelines for Crises in Anaesthesia
Evidence of fire (smoke, heat, odour, flash, flame)
Intraoperative Patient ... fire alarm • Dial ... #Airway #Fire #Anesthesiology ... #Anesthesia #Intraoperative ... Checklist #Diagnosis #Management
Cardiac Tamponade - Guidelines for Crises in Anaesthesia
Caused by an accumulation of blood, pus, effusion fluid
or iatrogenic causes ... Plan definitive management ... Cardiac #Tamponade #Anesthesiology ... #Anesthesia #Intraoperative ... Checklist #Diagnosis #Management
Distal Radius Fracture 
Distal radius fracture is the most common orthopedic injury. Here's a quick summary.
•
styloid fracture, median ... injury) • ED Management ... Colles #Distal #Radiology ... XRay #Diagnosis #Management ... #Orthopedics #MSK