41 results
CDC Recommended Laboratory HIV Testing Algorithm for Serum or Plasma Specimens

#HIV #Algorithm #Screening #Testing #HIVAIDS #Diagnosis
CDC Recommended ... Laboratory HIV Testing ... Algorithm for Serum ... Specimens #HIV #Algorithm ... #Screening #Testing
"Recommended laboratory HIV testing algorithm for serum or plasma specimens. Based on: Centers for Disease Control
laboratory HIV testing ... algorithm for serum ... Laboratory Testing ... #HIV #CDC #Diagnosis ... #Algorithm #InfectiousDisease
Cholecystitis Diagnostic Test Characteristics  

Sensitivity, Specificity and Likelihood Ratios of Labs, Physical Exam findings, and
Characteristics Sensitivity ... Cholecystitis #Testing ... Characteristics #Table ... #Sensitivity #Specificity
Step by Step Algorithmic Approach to Pediatric Fever

Age < 21 days old (or 28 days for
Step by Step Algorithmic ... days for improved sensitivity ... >= 0.5 ng/mL CRP ... Management #StepByStep #Algorithm
Performance Characteristics for Colorectal Cancer Screening Tests
Stool/blood-based tests:
 • FIT: 79% sensitivity, 94% specificity for CRC
tests: • FIT: 79% sensitivity ... DNA test: 92% sensitivity ... for CRC, Poor sensitivity ... Tests #comparison #table ... #Testing
Iron Deficiency Anemia vs Anemia of Chronic Disease - Laboratory Testing

SUMMARY:
 - RDW, FEP, serum iron,
Disease - Laboratory Testing ... normal but poor sensitivity ... Disease #Laboratory #Testing ... #Comparison #Table
ACA Colorectal Cancer Screening Guidelines

When to Screen?
When to Stop?
Family History

Performance Characteristics for Colorectal Cancer Screening Tests
Stool/blood-based
: • FIT: 79% sensitivity ... DNA test: 92% sensitivity ... for CRC, Poor sensitivity ... Tests #comparison #table ... #Testing #Indications
Diagnostic algorithm for the workup of hypercalcemia. The diagnostic workup for patients presenting with hypercalcemia rests
Diagnostic algorithm ... value of 0.0115, sensitivity ... for correct classification ... Thus, further testing ... #Differential #Algorithm
A priority in this project was to appropriately stratify participants into a low, medium, or high-intensity
The classification ... developed by the CDC ... , entitled “Algorithm ... The algorithm is ... developed by the CDC
Management Algorithm for Confusion
- Substrate verification, glucose, oxygen checks
- Toxidrome present
- Focal findings on neurologic examination
-
Management Algorithm ... criteria - ED testing ... examination, basic (CBC ... Delirium #Management #Algorithm