20 results
Effective radiation dose in adults - Following are comparisons of effective radiation dose in adults with
Effective radiation dose ... Following are comparisons ... #PatientInfo #Radiology ... #CT #Nuclear #Comparison ... #Table #Risks
Small Bowel Obstruction Testing Accuracy
#Diagnosis #SBO #Testing #Accuracy #Sensitivity #Specificity #KUB #AbdominalXRay #CT #POCUS #LikelihoodRatio #Comparison
Accuracy #Diagnosis ... #SBO #Testing # ... Accuracy #Sensitivity ... LikelihoodRatio #Comparison ... #Table
Cholecystitis Diagnostic Test Characteristics  

Sensitivity, Specificity and Likelihood Ratios of Labs, Physical Exam findings, and
Characteristics Sensitivity ... Cholecystitis #Testing ... Characteristics #Table ... #Sensitivity #Specificity ... LikelihoodRatio #Accuracy
Monoclonal Gammopathy Testing
Strengths, Weaknesses and Accuracy Compared
 - SPEP 
 - IFE 
 - FLC
Monoclonal Gammopathy Testing ... Weaknesses and Accuracy ... Monoclonal #Gammopathy #Testing ... Nephrology #Laboratory #Comparison ... #Table
Emergency physician interpretation of point-of-care ultrasound for identifying and grading of hydronephrosis in renal colic compared
Hydronephrosis #Comparison ... #Accuracy #Sensitivity ... #Specificity #Testing
Medical Imaging - Radiation Dose
#PatientInfo #Radiology #Procedures #Imaging #Radiation #Doses #ChestXRay #CT #Nuclear #Stress #Comparison #Table
Imaging - Radiation Dose ... #PatientInfo # ... Imaging #Radiation #Doses ... Nuclear #Stress #Comparison ... #Table #Risks
Estimated Medical Radiation Doses for 5 Year-Old Child

3-view ankle	0.0015 mSv	1/14th CXRs
2-view chest	0.02 mSv	1 CXRs
Anteroposterior and lateral
Medical Radiation Doses ... Pediatrics 2008 #PatientInfo ... #CT #Nuclear #Comparison ... #Table #Risks # ... Testing #Study #
Iron Deficiency Anemia vs Anemia of Chronic Disease - Laboratory Testing

SUMMARY:
 - RDW, FEP, serum iron,
Disease - Laboratory Testing ... normal but poor sensitivity ... Disease #Laboratory #Testing ... #Comparison #Table
Helicobacter Pylori Testing  Methods - Sensitivity and Specificity

Serology - 85% - 79% - Does not
Helicobacter Pylori Testing ... Methods - Sensitivity ... - 85% - 79% - Does ... other means of testing ... Laboratory #Diagnosis #Accuracy
Imaging Modalities for Renal Calculus

AXR. KUB
 - Good far calcium-containing stones useful when limited radiation dose
limited radiation dose ... non-invasive - High sensitivity ... Rapid. highly accurate ... renal stones - Accurate ... obstruction - Able