13 results
Differential diagnosis on HRCT
Most of our knowledge about imaging findings in interstitial lung disease comes from
Differential diagnosis on HRCT ... disease comes from HRCT ... On HRCT there are ... low attenuation (table ... When the cysts have
Low Attenuation pattern 
1. Lymphangiomyomatosis (LAM): uniform cysts in woman of child-bearing age; no history of
Low Attenuation pattern ... (LAM): uniform cysts ... bizarre shaped cysts ... Clinical #Radiology #HRCT ... #Comparison #Table
Low Attenuation pattern (2) 
1. Centrilobular emphysema: low attenuation areas without walls. Notice the centrilobular artery
Low Attenuation pattern ... multiple thick walled cysts ... (LAM): regular cysts ... Clinical #Radiology #HRCT ... #Comparison #Table
Nodular pattern(2)
1. Sarcoidosis: nodules with perilymphatic distribution, along fissures, adenopathy.
2. TB: Tree-in-bud appearance in a patient
Nodular pattern( ... before the typical cysts ... Clinical #Radiology #HRCT ... CTChest #Nodular #Pattern ... #Comparison #Table
Additional Modalities for Workup of GI Bleed (Other than EGD + Colonoscopy)

Pill endoscopy
 • Able to
endoscopy • Able ... endoscopy limits, high sensitivity ... bowel duplication cysts ... Bleed #GIBleed #management ... gastroenterology #table
Preoperative Risk Evaluation

Major Pre-Op Questions:
1. Does the patient have any modifiable risk factors that could be
functional status - Able ... metabolic equivalent able ... event, follow ACC algorithm ... Stable patients ... medical and surgical management
CA-Bridge Buprenorphine Hospital Quick Start Algorithm - Management of acute opiate withdrawal 
 - Any prescriber
Hospital Quick Start Algorithm ... - Management of ... effective for treating ... If patient is stable ... dosing TID/QID #Management
Aortoenteric Fistula - Diagnosis and Management Summary
Epidemiology:
• Uncommon but life-threatening
• Most common site of bowel connection
Diagnosis and Management ... intervention, no matter ... the OR • HD stable ... undergo EGD - Sensitivity ... about 50% • Stable
Performance Characteristics for Colorectal Cancer Screening Tests
Stool/blood-based tests:
 • FIT: 79% sensitivity, 94% specificity for CRC
tests: • FIT: 79% sensitivity ... DNA test: 92% sensitivity ... Tests #comparison #table ... #management #gastroenterology ... #CRC #Testing
ACA Colorectal Cancer Screening Guidelines

When to Screen?
When to Stop?
Family History

Performance Characteristics for Colorectal Cancer Screening Tests
Stool/blood-based
: • FIT: 79% sensitivity ... DNA test: 92% sensitivity ... Tests #comparison #table ... #management #gastroenterology ... #CRC #Testing #