11 results
Cholecystitis Diagnostic Test Characteristics  

Sensitivity, Specificity and Likelihood Ratios of Labs, Physical Exam findings, and
Cholecystitis Diagnostic Test ... Cholecystitis #Testing ... Characteristics #Table ... #Sensitivity #Specificity ... LikelihoodRatio #Accuracy
Performance Characteristics for Colorectal Cancer Screening Tests
Stool/blood-based tests:
 • FIT: 79% sensitivity, 94% specificity for CRC
, 94% specificity ... stool DNA test: ... for CRC, Poor sensitivity ... #comparison #table ... #Testing
ACA Colorectal Cancer Screening Guidelines

When to Screen?
When to Stop?
Family History

Performance Characteristics for Colorectal Cancer Screening Tests
Stool/blood-based
, 94% specificity ... stool DNA test: ... for CRC, Poor sensitivity ... #comparison #table ... #Testing #Indications
Small Bowel Obstruction Testing Accuracy
#Diagnosis #SBO #Testing #Accuracy #Sensitivity #Specificity #KUB #AbdominalXRay #CT #POCUS #LikelihoodRatio #Comparison
Accuracy #Diagnosis ... #SBO #Testing # ... Accuracy #Sensitivity ... #Specificity #KUB ... LikelihoodRatio #Comparison #Table
Commonly Used Diagnostic Tests for Celiac Disease

Tissue transglutaminase (tTG) IgA antibodies
 - Most reliable noninvasive test
- High sensitivity ... and specificity ... and specificity ... Celiac #Disease #Testing ... Diagnosis #Workup #Table
Helicobacter Pylori Testing  Methods - Sensitivity and Specificity

Serology - 85% - 79% - Does not
Methods - Sensitivity ... and Specificity ... Urea breath test ... at UCSF due to cost ... Laboratory #Diagnosis #Accuracy
Diagnostic algorithm for the workup of hypercalcemia. The diagnostic workup for patients presenting with hypercalcemia rests
Diagnostic algorithm ... value of 0.0115, sensitivity ... ) was 0.80 and specificity ... Thus, further testing ... #Differential #Algorithm
Diagnosis Adrenal Insufficiency - Algorithm

Step 1) Screening Test: 6-8AM Cortisol Level
 - Early morning cortisol levels
Insufficiency - Algorithm ... have almost 100% specificity ... for AI (but low sensitivity ... require Cosyntropin testing ... Insufficiency #Algorithm
Celiac Disease - Diagnosis Algorithm
IgA TTG has high sensitivity and specificity of ~ 98% and is
Disease - Diagnosis Algorithm ... IgA TTG has high sensitivity ... and specificity ... pts need further testing ... Disease #Diagnosis #Algorithm
Preoperative Risk Evaluation

Major Pre-Op Questions:
1. Does the patient have any modifiable risk factors that could be
event, follow ACC algorithm ... determine if stress test ... Stable patients ... surgery Stress Testing ... preoperative stress testing