13 results
Commonly Used Diagnostic Tests for Celiac Disease

Tissue transglutaminase (tTG) IgA antibodies
 - Most reliable noninvasive test
Used Diagnostic Tests ... reliable noninvasive test ... first-level screening test ... #Testing #Laboratory ... #Workup #Table
Syncope Diagnostic Testing and Evaluation: Cost Effectiveness
Frequency obtained - Abnormal findings - Helped determine etiology of
- Cost per test ... etiology of syncope Tests ... Cardiac stress test ... #testing #Cost ... #comparison
Iron Deficiency Anemia vs Anemia of Chronic Disease - Laboratory Testing

SUMMARY:
 - RDW, FEP, serum iron,
Anemia of Chronic Disease ... - Laboratory Testing ... normal but poor sensitivity ... non-invasive test ... #Comparison #Table
Performance Characteristics for Colorectal Cancer Screening Tests
Stool/blood-based tests:
 • FIT: 79% sensitivity, 94% specificity for CRC
Cancer Screening Tests ... Stool/blood-based tests ... Multitarget stool DNA test ... colon #Screening #Tests ... #comparison #table
ACA Colorectal Cancer Screening Guidelines

When to Screen?
When to Stop?
Family History

Performance Characteristics for Colorectal Cancer Screening Tests
Stool/blood-based
Cancer Screening Tests ... Stool/blood-based tests ... Multitarget stool DNA test ... #Indications #Tests ... #comparison #table
Rheumatology Workup - Laboratories Studies in Rheumatic Diseases

• Septic arthritis - Gram stain and culture of
Rheumatology Workup ... antibody (ANA) test ... ; if positive, test ... has higher specificity ... but lower sensitivity
Diagnostic algorithm for the workup of hypercalcemia. The diagnostic workup for patients presenting with hypercalcemia rests
Diagnostic algorithm ... value of 0.0115, sensitivity ... ) was 0.80 and specificity ... Thus, further testing ... #Differential #Algorithm
Diagnostic algorithm for a child or adolescent with suspected pulmonary hypertension. CHD, congenital heart disease; CPET,
Diagnostic algorithm ... cardiopulmonary exercise testing ... liver function test ... #Hypertension #Workup ... #Algorithm
Diagnosis Adrenal Insufficiency - Algorithm

Step 1) Screening Test: 6-8AM Cortisol Level
 - Early morning cortisol levels
Step 1) Screening Test ... have almost 100% specificity ... for AI (but low sensitivity ... ) Confirmation Test ... This test determines
Celiac Disease - Diagnosis Algorithm
IgA TTG has high sensitivity and specificity of ~ 98% and is
IgA TTG has high sensitivity ... and specificity ... pts need further testing ... -A negative test ... -A positive test