12 results
Comparison of Fever Algorithms for Infants <3 months old

AGE, INCLUSION, TESTS 
REQUIRED, "LOW RISK" CRITERIA, TREATMENT,
Comparison of Fever ... Algorithms for ... #EBM #Fever #Algorithm ... #Comparison #Table ... #Performance
Performance Characteristics for Colorectal Cancer Screening Tests
Stool/blood-based tests:
 • FIT: 79% sensitivity, 94% specificity for CRC
Performance Characteristics ... specificity for CRC ... Screening #Tests #comparison ... #table #management ... #Testing
ACA Colorectal Cancer Screening Guidelines

When to Screen?
When to Stop?
Family History

Performance Characteristics for Colorectal Cancer Screening Tests
Stool/blood-based
Family History Performance ... specificity for CRC ... Indications #Tests #comparison ... #table #management ... #Testing #Indications
Relapsing Acute Severe Ulcerative Colitis - Management Algorithm
Loss of Response:
 • (Re)consult Colorectal Surgery
 • Assess
Colitis - Management Algorithm ... Flex Sig, FCP, CRP ... Cross-Sectional Imaging ... Multidisciplinary Meeting ... UC #Management #Algorithm
Estimated Medical Radiation Doses for 5 Year-Old Child

3-view ankle	0.0015 mSv	1/14th CXRs
2-view chest	0.02 mSv	1 CXRs
Anteroposterior and lateral
Radiation #Doses #Imaging ... #CT #Nuclear #Comparison ... #Table #Risks # ... Testing #Study #
Radiation Dose to Adults from Common Imaging Examinations
ABDOMINAL REGION
 - Computed Tomography (CT) — Abdomen and
Adults from Common Imaging ... 1 year MEN’S IMAGING ... #CT #Nuclear #Comparison ... #Table #Risks # ... Testing #Study
Preoperative Risk Evaluation

Major Pre-Op Questions:
1. Does the patient have any modifiable risk factors that could be
Performance thorough ... event, follow ACC algorithm ... Stable patients ... surgery Stress Testing ... preoperative stress testing
Fever of Unknown Origin (FUO) Diagnostic Algorithm
STEP 1 Perform a comprehensive history and complete physical examination.
STEP
FUO) Diagnostic Algorithm ... venous duplex imaging ... positive first-tier testing ... 18FDG-PET/CT scan imaging ... FUO #Diagnosis #Algorithm
How much radiation is used in paediatric radiology examinations compared to other exposures?

Estimated dose - Days
Radiation #Doses #Imaging ... #CT #Nuclear #Comparison ... #Table #Risks # ... Testing #Study #
Perhaps quite too often, the knee-jerk reaction to an elevated Troponin is to call our friends
alterations in the setting ... only 5% of the resting ... are typically able ... patient before making ... #diagnosis #algorithm