10 results
Lung POCUS for Diagnosis of CHF - Visual Abstract
What is the accuracy of combined Lung Ultrasound
Specificity - 95.5 - LR ... + 20.9 - LR- 0.07 ... Specificity - 89.4 - LR ... + 8.0 - LR- 0.17 ... #diagnosis #ebm
POCUS for diagnosis of Diverticulitis - Visual Abstract
What are the test characteristics of point-of-care ultrasonography in
POCUS for diagnosis ... Sensitivity - 97% ... Specificity - 92% LR ... + 30.7 LR- 0.08 ... ultrasound #diagnosis #ebm
3 Point POCUS for DVT - Visual Abstract
How accurately can emergency physicians diagnose lower extremity DVTs
3 Point POCUS for ... - Sensitivity - ... Specificity - 90% - LR ... + 9.32 - LR- 0.08 ... ultrasound #diagnosis #ebm
The value of point-of-care ultrasound for detecting nail bed injury in [the] ED

American Journal of Emergency
sens (CI 80-99), -LR ... (CI 74-100), +LR ... (CI 79-100), -LR ... (CI 91-100), +LR ... #Ultrasound #EBM
Point of Care Ultrasound for Appendicitis - Visual Abstract

Can emergency physicians diagnose appendicitis with high specificity
Specificity 97.9% + LR ... 20.6 - LR 0.58 ... Michael Prats #POCUS ... #Specificity #Likelihood ... #EBM
Acute Coronary Syndrome - Diagnostic Likelihood Ratios for Symptoms and Physical Examination. 

Source:  Does This
Syndrome - Diagnostic Likelihood ... #EBM #Diagnosis ... LikelihoodRatios #LR
Acute Coronary Syndrome - Diagnostic Likelihood Ratios for Symptoms and Physical Examination. Source: Fanaroff AC, Rymer
Syndrome - Diagnostic Likelihood ... #EBM #Diagnosis ... LikelihoodRatios #LR
This requires defining some general cutoff values for likelihood ratios.  These are admittedly arbitrary, but
Weak impact: +LR ... between 1-3 or a -LR ... Moderate impact: +LR ... Strong impact: +LR ... >10 or a -LR <1
POCUS for diagnosis of Wall Motion Abnormalities in Myocardial Infarction - Visual Abstract
Can physicians with limited
POCUS for diagnosis ... • RWMA +LR 11.5, ... -LR 0.13 • Localization ... +LR 5.4, -LR 0.1 ... ultrasound #diagnosis #ebm
POCUS for Small Bowel Obstruction - Visual Abstract
What is the accuracy of point of care ultrasound
POCUS for Small ... Sensitivity - 88% ... Specificity - 54% LR ... + 1.92 LR- 0.22 ... #diagnosis #ebm