64 results
POCUS Echocardiography - Table of Cardiac Views and Windows
 • Parastemal Long-Axis View (PLAX)
 • Parasternal
• SC Abdominal Aorta ... Axis • PSAX: Aortic ... Valve (AV) Level ... #TTE #Echocardiogram ... Echocardiography #Cardiology
Bicuspid Aortic Valve on Echocardiogram
Bicuspid Aortic valves (prevalence approx 2%) degenerate more frequently and rapidly (at
Bicuspid Aortic ... Valve on Echocardiogram ... and rapidly (at least ... #Valve #psax #Echocardiogram ... #clinical #cardiology
Quadricuspid Aortic Valve on Cardiac MRI with Severe Aortic Regurgitation
54 yo/ severe aortic regurgitation.  CMR
Valve on Cardiac ... valve with partial ... non-coronary cusps, and partial ... Regurgitation #CardiacMRI #clinical ... #cardiology
Mitral Stenosis and Left Atrial Thrombus on Echocardiogram (a4c)

Mitral stenosis is a risk factor for LA
Stenosis and Left Atrial ... (a4c) Mitral ... of underlying cardiac ... #Thrombus #a4c ... #clinical #cardiology
Cardiac Valve Replacement - Anticoagulation INR Targets and Antiplatelet by Valve Type

Bioprosthetic valves require at least
Cardiac Valve Replacement ... require at least ... patients with chronic atrial ... (2017 AHA/ACC VHD ... #Management #Cardiology
Cardiac Rupture with Pericardial Effusion

Apical 4 chamber. Note larger right sided pericardial effusion with significant compression
Cardiac Rupture ... pericardial #effusion #tamponade ... MyocardialInfarction #AMI #POCUS #Echocardiogram ... #ultrasound #Cardiology ... #A4c #clinical
The cardiac cycle describes each heart beat, incorporating relaxation and contraction. Phase one describes diastole and
The cardiac cycle ... describes each heart beat ... Aortic pressure ... valve closes and ... #Pathophys #Cardiology
Pulse Abnormalities - Differential Diagnosis Algorithm
Unequal/DeIayed:
 • Obstructive arterial disease (ie. Atherosclerosis)
 • Aortic dissection
 •
• Obstructive arterial ... with alternate beats ... pressure >10mmHg: • Cardiac ... tamponade • AECOPD ... Abnormalities #Disorders #Cardiology
Atrial Fibrillation on POCUS Echocardiogram (A4C)

35yoF presents with acute onset atrial fibrillation.  POCUS shows dilated
on POCUS Echocardiogram ... (A4C) 35yoF ... & poor mitral valve ... #A4C #clinical ... #cardiology
Aortic and Mitral Valve Regurgitaton on Parasternal long axis (PLAX)

Parasternal long axis (PLAX) is part of
Valve Regurgitaton ... of your basic cardiac ... #Mitral #Valve ... Regurgitaton #PLAX #clinical ... #cardiology #echocardiogram