Cardiac Valve Replacement - Anticoagulation INR Targets and Antiplatelet by Valve Type

Bioprosthetic valves require at least
Cardiac Valve Replacement ... Antiplatelet by Valve ... Bioprosthetic valves ... utilize direct oral ... #Target #DOAC #Table
POCUS Echocardiography - Table of Cardiac Views and Windows
 • Parastemal Long-Axis View (PLAX)
 • Parasternal
Echocardiography - Table ... -Chamber View (A4C ... • PSAX: Aortic Valve ... • PSAX: Mitral Valve ... #Cardiac #TTE #Echocardiogram
Lymphoma infiltration in mitral valve on Echocardiogram
A case from my archive... interesting. Lymphoma infiltration in mitral
infiltration in mitral valve ... infiltration in mitral valve ... infiltration of the valve ... went to mitral valve ... pocus #plax #psax #a4c
Severity of Aortic Stenosis in Adults 
Current ACC/AHA guidelines recommend cut-off values for Doppler-echocardiographic measurements of
Adults Current ACC ... recommend cut-off values ... follows: aortic valve ... >50 mmHg (2) (Table ... with impaired and normal
Causes of Extravascular and Intravascular Hemolysis - Differential Diagnosis Algorithm
Extravascular - Spleen and RES-mediated hemolysis
 -
Causes of Extravascular ... Differential Diagnosis Algorithm ... Drug-induced AIHA - Abnormal ... Prosthetic heart valves ... #Causes #Hematology
Echocardiography
Right ventricular function can be assessed using several methods and echocardiography is generally the first‐line tool
independent prognostic value ... lower limit of normal ... predictive of all‐cause ... Cardiology #POCUS #Echocardiogram
Mitral Valve Vegetations in Endocarditis - POCUS Echocardiogram

Apical 4-chamber view, a mobile echogenic mass is seen
Mitral Valve Vegetations ... to the mitral valve ... in & out of the LA ... EUSmkh #Mitral #Valve ... clinical #cardiology #a4c
Atrial Fibrillation on POCUS Echocardiogram (A4C)

35yoF presents with acute onset atrial fibrillation.  POCUS shows dilated
Fibrillation on POCUS Echocardiogram ... (A4C) 35yoF ... & poor mitral valve ... seen from LV to LA ... #A4C #clinical
Ebstein Anomaly on Echocardiogram

Ebstein anomaly. The tricuspid valve is ALWAYS more apically displaced than the mitral
The tricuspid valve ... than the mitral valve ... apically displaced valved ... therefore the valve ... #cardiology #a4c
Microcavitation due to mechanical valve closure (aortic in this case).

Dissolved gas changing state due to changes
to mechanical valve ... aortic in this case ... pressure that causes ... #Ventricular #Echocardiogram ... POCUS #Clinical #A2C